MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1080/09593330.2024.2447961

Медицинская библиотека · Environmental technology · 2025

Improvement of the three-dimensional electrochemical degradation of amoxicillin using Co3O4/GAC as both particle electrode and catalyst for peroxymonosulfate activation.

Ma Jinsong, Hyon Songchol, Kim Sunghyok, Ri Tong Chol

СтатьяПеревод в очереди

Аннотация

In this study, a novel three-dimensional (3D) electrode system (3D-Co3O4/GAC-PMS) was constructed that can effectively degrade amoxicillin (AMX) in aqueous solution using granular activated carbon (GAC) loaded with Co3O4 catalyst (Co3O4/GAC) as a catalyst for the activation of peroxymonosulfate (PMS) as well as particle electrode. The effects of the main operating parameters on AMX degradation, TOC removal, electrical energy consumption and current efficiency were investigated. Under the optimum operating conditions (initial solution pH of 5.9, PMS concentration of 13 mmol/L, current density of 5.6 mA/cm2), 99.9% of AMX was degraded after 10 min of treatment and 96.8% of TOC was removed after 120 min of treatment. Meanwhile, the electrical energy consumption of the system was very small, only 45.1 kWh/kg TOC. Comparative experiments with other systems and kinetic analysis have confirmed the superior performance of the 3D-Co3O4/GAC-PMS system for the degradation of AMX. During five cycles, the Co3O4/GAC particle electrode showed excellent stability and long lifetime. The 3D-Co3O4/GAC-PMS system simultaneously degraded 100% of three different pharmaceuticals (amoxicillin, ciprofloxacin and acetaminophen) after 8 min of reaction and removed 88.1% TOC after 120 min of reaction, which suggested the applicability of the system for real wastewater treatment. The degradation of AMX was confirmed using UV-Vis spectroscopy and the reaction mechanism of the 3D-Co3O4/GAC-PMS system was proposed. Based on the intermediates detected by ultra-high pressure liquid chromatograph coupled with quadrupole time-of-flight mass-spectrometry, the degradation pathways of AMX in the 3D-Co3O4/GAC-PMS system were presented.

Для цитирования: Ma Jinsong, Hyon Songchol, Kim Sunghyok, Ri Tong Chol. Improvement of the three-dimensional electrochemical degradation of amoxicillin using Co3O4/GAC as both particle electrode and catalyst for peroxymonosulfate activation.. Environmental technology. 2025. DOI: 10.1080/09593330.2024.2447961.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.