MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/s0266-6138(03)00020-2

Медицинская библиотека · Midwifery · 2003

A randomised controlled trial of admission electronic fetal monitoring in normal labour.

Cheyne Helen, Dunlop Aileen, Shields Noreen, Mathers Alan M

Клиническое исследованиеСтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

AIM: To test the hypothesis that the use of admission Electronic Fetal Monitoring (EFM) for healthy pregnant women in spontaneous labour would result in an increase in continuous EFM when compared to women who have had no admission EFM.

DESIGN

A randomised controlled trial.

SETTING

The Midwives Birth Unit in Glasgow Royal Maternity Hospital, a major urban teaching hospital with approximately 5000 births per year.

PARTICIPANTS

Healthy pregnant women admitted in normal labour, deemed low risk based on the midwives' birth unit admission criteria.

INTERVENTION: Women were randomly allocated either to receive a routine 20-minute period of EFM at the time of admission (control group), or to receive no routine admission EFM (study group).

OUTCOME MEASURES: Primary study outcomes, use of continuous EFM; and use of EFM additional to the admission test.

SECONDARY OUTCOMES: artificial rupture of membranes, use of fetal scalp electrode, fetal blood sample, syntocinon, epidural analgesia, number of vaginal examinations, rate of transfer to labour ward, and reason for transfer.

KEY FINDINGS: There was no statistically significant difference between the groups for use of continuous monitoring, but significantly more women in the control group did receive additional EFM. There was no statistically significant difference between groups for any of the interventions studied.

CONCLUSION

The use of admission EFM did not in itself lead to a cascade of intervention. Other factors including setting of care and philosophy of caregivers may have an effect on the rate of intervention in labour.

Для цитирования: Cheyne Helen, Dunlop Aileen, Shields Noreen, Mathers Alan M. A randomised controlled trial of admission electronic fetal monitoring in normal labour.. Midwifery. 2003. DOI: 10.1016/s0266-6138(03)00020-2.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.