DOI 10.1177/230949901001800306
Mechanical thromboprophylaxis for patients undergoing hip fracture surgery.
Аннотация
PURPOSE: To evaluate the rates of deep vein thrombosis (DVT) and pulmonary embolism (PE) in hip fracture patients receiving mechanical thromboprophylaxis.
METHODS
123 men and 311 women (mean age, 76 years) admitted to our institution with hip fractures were included. 95% of patient received mechanical prophylaxis using pneumatic calf pumps intermittently for 20 hours or less per day before and after surgery. At the surgeon's discretion, 161 (37%) of them received concomitant chemical prophylaxis in the form of subcutaneous low-molecular-weight heparin (enoxaparin). Signs and symptoms of DVT and PE were monitored daily, as were calf and thigh circumference. Diagnoses were confirmed by duplex ultrasonography of the lower limbs and/or spiral computed tomography scan of the thorax.
RESULTS
13 patients developed symptomatic venous thromboembolism (VTE); 11 were DVT and 2 were PE. Among DVT patients, 2 had proximal and 9 had distal DVT. All these patients underwent anticoagulation and were discharged without any complications. No patients developed complications from pneumatic calf pumps (foot drop, skin abrasions or stasis). Eight patients developed bleeding tendencies during hospitalisation. No patient developed surgical wound infections. 12 patients died during hospitalisation; 8 of them from acute myocardial infarction or pneumonia, and none from PE. The median length of hospital stay was significantly longer in patients with VTE.
CONCLUSION
Routine use of mechanical thromboprophylaxis is recommended in patients undergoing hip fracture surgery.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.