Tsesis Igor, Kamburoğlu Kivanc, Katz Alexander, Tamse Aviad, Kaffe Israel, Kfir Anda
Аннотация
OBJECTIVE: The purpose of the present study was to compare the diagnostic ability of conventional intraoral film radiography and a charged-coupled device (CCD) sensor in detecting vertical root fractures (VRF) in endodontically treated single-rooted extracted human maxillary premolars.
STUDY DESIGN: The study consisted of 60 extracted single-rooted endodontically treated maxillary premolars: 30 with clinically confirmed VRF (experimental group) and 30 with no VRF (control group). An intraoral CCD sensor and conventional Kodak Insight Film were used. Two observers evaluated the digital and conventional radiographs twice with an interval of 4 weeks. Specificity and sensitivity for each radiographic technique were calculated and subjected to statistical analysis. Kappa values were calculated for intra- and interobserver agreement. Fisher's exact test was used to evaluate detection of VRF. The overall differences in sensitivity and specificity between radiographic techniques were evaluated by McNemar test.
RESULTS: The specificity of the digital system was significantly better (P = .016) for the second observer at the first reading. There were no significant differences in sensitivity and specificity for both observers between the 2 systems for other readings (P > .05).
CONCLUSIONS: No difference was found between the intraoral CCD sensor and conventional radiography in detecting vertical root fractures for single rooted maxillary premolars ex vivo.
STUDY DESIGN: The study consisted of 60 extracted single-rooted endodontically treated maxillary premolars: 30 with clinically confirmed VRF (experimental group) and 30 with no VRF (control group). An intraoral CCD sensor and conventional Kodak Insight Film were used. Two observers evaluated the digital and conventional radiographs twice with an interval of 4 weeks. Specificity and sensitivity for each radiographic technique were calculated and subjected to statistical analysis. Kappa values were calculated for intra- and interobserver agreement. Fisher's exact test was used to evaluate detection of VRF. The overall differences in sensitivity and specificity between radiographic techniques were evaluated by McNemar test.
RESULTS: The specificity of the digital system was significantly better (P = .016) for the second observer at the first reading. There were no significant differences in sensitivity and specificity for both observers between the 2 systems for other readings (P > .05).
CONCLUSIONS: No difference was found between the intraoral CCD sensor and conventional radiography in detecting vertical root fractures for single rooted maxillary premolars ex vivo.