MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1378/chest.09-2721

Медицинская библиотека · Chest · 2010

Laser tissue welding in lung and tracheobronchial repair: an animal model.

Bleier Benjamin S, Cohen Neri M, Bloom Jason D, Palmer James N, Cohen Noam A

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

BACKGROUND

Violation of the integrity of the airway (pulmonary parenchymal air leak or tracheobronchial injury) remains a challenging problem in chest medicine and thoracic surgery. Tissue sealants such as fibrin glue have been suggested to improve outcomes but they are still associated with significant failure rates. Laser tissue welding (LTW) is an alternative method that produces wound repairs that are significantly stronger than those of fibrin glue and may be used to repair air leaks.

METHODS

We used an Institutional Animal Care and Use Committees-approved New Zealand white rabbit model of lung parenchymal and tracheal injury. Lung wounds (n = 8 per condition) were created and either left open or repaired using fibrin glue or LTW. Tracheal wounds (n = 5 per condition) were created using incisions in the membranous and cartilaginous portions or by removing a tracheal ring, and were repaired using LTW. Within each tissue type, the burst strength of the wounds was measured using a digital manometer and were compared with one another using a two-tailed, paired Student t test.

RESULTS

Among the lung injuries, the burst strength of the LTW repair (19.95 +/- 4.98 mm Hg) was significantly stronger than that of the fibrin glue repair or open wound (10.53 +/- 5.01 mm Hg, P = .001, and 7.61 +/- 2.64 mm Hg, P < .001, respectively). Among the tracheal injuries, the burst strength of the membranous incision (101.00 +/- 20.25 mm Hg) was significantly higher than that of the cartilaginous incision (75.08 +/- 10.50 mm Hg, P = .03) but not that of the cartilaginous defect (77.34 +/- 12.35 mm Hg).

CONCLUSIONS

LTW is capable of sealing wounds in the tracheobronchial tree and can produce bonds that are twice as strong as fibrin glue in lung parenchyma. LTW may be a better alternative than fibrin glue in the repair of injuries to the airway.

Для цитирования: Bleier Benjamin S, Cohen Neri M, Bloom Jason D, Palmer James N, Cohen Noam A. Laser tissue welding in lung and tracheobronchial repair: an animal model.. Chest. 2010. DOI: 10.1378/chest.09-2721.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.