Intraocular pressure following ECCE, phacoemulsification, and PC-IOL implantation.
Аннотация
Abnormal intraocular pressure (IOP), either transient or permanent, may follow extracapsular cataract extraction (ECCE) with phacoemulsification (PE) and posterior chamber intraocular lens (PC-IOL) implantation. We retrospectively studied IOP measurements at different intervals post ECCE and PE in 242 eyes of 211 patients: 105 males, 106 females, 198 Caucasians and 13 blacks. Elevated IOP (greater than 23 mm Hg) was observed in 20 eyes (8.2%). Only two patients (0.8%) had persistent (greater than 3 months) IOP elevation and needed antiglaucoma therapy. Six more eyes (2.5%), however, developed glaucoma after 1 year. Hence, the incidence of secondary pseudophakic glaucoma at the conclusion of this study was 3.3%. No patient required laser or other mechanical surgery for IOP control. ECCE and PE with PC-IOL does not appear to adversely affect IOP. Patients, however, must be followed closely, as some may develop glaucoma months after surgery.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.