[Diagnostic accuracy of a hysteroscopic score for the detection of endometrial cancer in patients with postmenopausal bleeding and endometrial thickening].
Аннотация
OBJECTIVE
To assess the diagnostic accuracy of hysteroscopic scores in endometrial cancer.
METHODS
Diagnostic accuracy study assembled within a cross-sectional study that included patients with postmenopausal bleeding and endometrial thickening greater than 5 mm in whom hysteroscopy was performed and then compared with endometrial biopsy as the diagnostic gold standard, in two high complexity hospitals. Clinical, sociodemographic variables, as well as hysteroscopic scores and the results of endometrial tissue histopathology were measured. Sensitivity and specificity, likelihood ratios and area under the curve with their respective confidence intervals were estimated in the analysis.
RESULTS
With a 9 % prevalence of endometrial cancer, the hysteroscopic assessment system was shown to have 75 % sensitivity (95 % CI; 30.1- 95.43), 95,1 % specificity (95 % CI; 83.9-98.7), a positive likelihood ratio of 15.38 (95 %; CI 3.55- 66.56), a negative likelihood ratio of 0.26 and area under the curve of 85 %.
CONCLUSIONS
The standardized hysteroscopic assessment system was found to have an acceptable sensitivity for screening in patients with postmenopausal bleeding and endometrial thickening (≥ 5 mm). Further studies with larger sample sizes are required in order to arrive at a more precise estimation of the operational characteristics of the hysteroscopic assessment system for the detection of endometrial cancer.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.