DOI 10.19723/j.issn.1671-167x.2021.04.020
[Application of Rotarex mechanical thrombectomy system in treating in-stent restenosis of lower extremity arteriosclerosis obliterans].
Аннотация
OBJECTIVE
To evaluate the role of Rotarex mechanical thrombectomy system in treating instent restenosis of peripheral artery disease (PAD).
METHODS
The clinical data of 7 in-stent restenosis (ISR) cases of lower extremity PAD from June 2017 to Dec 2018 were retrospectively analyzed. There were 5 males and 2 females and the mean age was (70.0±7.6) years from 59.0 to 76.0 years. All the cases were treated by Rotarex mechanical thrombectomy system. In the 7 cases, time interval from the previous stent implantation to ischemia recurrence was 1.0 to 72.0 months, and the median time was 6.0 months. The period from ischemia recurrence to endovascular therapy was 3 days to 2 years, and the median time was 62 days. Rotarex mechanical debulking catheter and percutaneous transluminal angioplasty (PTA) were used in all the cases, and the stent was used only when it was necessary. Anticoagulation was used for 24 hours after procedures and then antiplatelet agents were used as usual. Doppler ultrasonography was taken during the followed-up.
RESULTS
All the 7 cases were successful in technology, 3 of which were implanted with new stents for the fracture of the old ones. while for the other four cases, no new stent was implanted. The ankle-brachial index (ABI) increased from 0.31±0.08 to 0.86±0.08 after treatment (t=-12.84, P < 0.001). Thrombectomy was applied urgently in one case because of acute thrombosis in the stent, and the result was good. There was no other complications in hospital. All the patients were followed up for 5.0-22.0 months, and the median time was 14.0 months. No death and amputation occurred during the follow-up. One patient stopped antiplatelet agents because of gastrointestinal bleeding, which resulted in acute thrombosis. in-stent restenosis reappeared in 3 cases.
CONCLUSION
Debulking using Rotarex catheter is safe and effective in treating in-stent restenosis of PAD, especially in reducing stents implantation, but is not good at dealing with old thrombus and proliferating intima, and can do nothing about fractured stents and hyperplasia of intima, so it needs to be combined with stents and drug coated balloons.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.