MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/0363546514560156

Медицинская библиотека · The American journal of sports medicine · 2014

Biomechanical analysis of articular-sided partial-thickness rotator cuff tear and repair.

Mihata Teruhisa, McGarry Michelle H, Ishihara Yoko, Bui Christopher N H, Alavekios Damon, Neo Masashi, Lee Thay Q

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Articular-sided partial-thickness rotator cuff tears are common injuries in throwing athletes. The superior shoulder capsule beneath the supraspinatus and infraspinatus tendons works as a stabilizer of the glenohumeral joint.

PURPOSE: To assess the effect of articular-sided partial-thickness rotator cuff tear and repair on shoulder biomechanics. The hypothesis was that shoulder laxity might be changed because of superior capsular plication in transtendon repair of articular-sided partial-thickness rotator cuff tears.

STUDY

DESIGN

Controlled laboratory study.

METHODS

Nine fresh-frozen cadaveric shoulders were tested by using a custom shoulder-testing system at the simulated late-cocking phase and acceleration phase of throwing motion. Maximum glenohumeral external rotation angle, anterior translation, position of the humeral head apex with respect to the glenoid, internal impingement area, and glenohumeral and subacromial contact pressures were measured. Each specimen underwent 3 stages of testing: stage 1, with the intact shoulder; stage 2, after creation of articular-sided partial-thickness tears of the supraspinatus and infraspinatus tendons; and stage 3, after transtendon repair of the torn tendons by using 2 suture anchors.

RESULTS

Articular-sided partial-thickness tears did not significantly change any of the shoulder biomechanical measurements. In the simulated late-cocking phase, transtendon rotator cuff repair resulted in decreased maximum external rotation angle by 4.2° (P = .03), posterior shift of the humeral head (1.1-mm shift; P = .02), decreased glenohumeral contact pressure by 1.7 MPa (56%; P = .004), and decreased internal impingement area by 26.4 mm(2) (65%; P < .001) compared with values in the torn shoulder. In the acceleration phase, the humeral head shifted inferiorly (1.2-mm shift; P = .03 vs torn shoulder), and glenohumeral anterior translation (1.5-mm decrease; P = .03 vs torn shoulder) and subacromial contact pressure (32% decrease; P = .004 vs intact shoulder) decreased significantly after transtendon repair.

CONCLUSION

Transtendon repair of articular-sided partial-thickness supraspinatus and infraspinatus tears decreased glenohumeral and subacromial contact pressures at time zero; these changes might lead to reduced secondary subacromial and internal impingements and consequently progression to full-thickness rotator cuff tear. However, repair of the tendons decreased anterior translation and external rotation and changed the positional relationship between the humeral head and the glenoid.

CLINICAL RELEVANCE: Careful attention should be paid to shoulder laxity and range of motion when transtendon repair is chosen to treat articular-sided partial-thickness rotator cuff tears, specifically in throwing athletes.

Для цитирования: Mihata Teruhisa, McGarry Michelle H, Ishihara Yoko, Bui Christopher N H, Alavekios Damon, Neo Masashi, Lee Thay Q. Biomechanical analysis of articular-sided partial-thickness rotator cuff tear and repair.. The American journal of sports medicine. 2014. DOI: 10.1177/0363546514560156.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.