BACKGROUND & AIMS: To determine accuracy of endoscopic ultrasound (EUS) and magnetic resonance imaging (MRI) for evaluation of Crohn's disease perianal fistulas.

METHODS

Thirty-four patients with suspected Crohn's disease perianal fistulas were prospectively enrolled in a blinded study comparing EUS, MRI, and examination under anesthesia (EUA). Fistulas were classified according to Parks' criteria, and a consensus gold standard was determined for each patient. Acceptable accuracy was defined as agreement with the consensus gold standard for > or =85% of patients.

RESULTS

Three patients did not undergo MRI; 1 did not undergo EUS or EUA; and consensus could not be reached for 1. Thirty-two patients had 39 fistulas (20 trans-sphincteric, 5 extra-sphincteric, 6 recto-vaginal, 8 others) and 13 abscesses. The accuracy of all 3 modalities was > or =85%: EUS 29 of 32 (91%, confidence interval [CI] 75%-98%), MRI 26 of 30 (87%, CI 69%-96%), and EUA 29 of 32 (91%, CI 75%-98%). Accuracy was 100% when any 2 tests were combined.

CONCLUSIONS

EUS, MRI, and EUA are accurate tests for determining fistula anatomy in patients with perianal Crohn's disease. The optimal approach may be combining any 2 of the 3 methods.

Для цитирования: Schwartz D A, Wiersema M J, Dudiak K M, Fletcher J G, Clain J E, Tremaine W J, Zinsmeister A R, Norton I D, Boardman L A, Devine R M, Wolff B G, Young-Fadok T M, Diehl N N, Pemberton J H, Sandborn W J. A comparison of endoscopic ultrasound, magnetic resonance imaging, and exam under anesthesia for evaluation of Crohn's perianal fistulas.. Gastroenterology. 2001. DOI: 10.1053/gast.2001.28676.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.