Mini-laparoscopic placement of a peritoneal dialysis catheter.

Varela J E, Elli E F, Vanuno D, Horgan S

Оценочное исследованиеСтатьяПеревод в очереди

Аннотация

BACKGROUND

The laparoscopic placement of continuous ambulatory peritoneal dialysis (CAPD) catheters is now an accepted technique. We evaluated a new technique for CAPD catheter placement that requires only a single 2-mm port.

METHODS

A pilot study was conducted at an academic minimally invasive surgery center. Seven consecutive patients in whom a CAPD catheter was required underwent placement of a 2-mm Veress port and a laparoscope. A carbon dioxide pneumoperitoneum was induced up to 14 mmHg. Under direct visualization with a 2-mm scope, a CAPD catheter was advanced over the right lower quadrant toward the pelvis using a modified Seldinger technique.

RESULTS

Seven patients (four women and three men) with end-stage renal disease underwent mini-laparoscopic placement of a CAPD catheter. Mean patient age was 35.3 +/- 11.3 years (range, 17-50). Mean operative time was 20.7 +/- 5.0 min (range, 14-29). Patients were dialyzed in the immediate postoperative period. No leaks were identified, and there were no intraoperative or postoperative complications.

CONCLUSION

A mini-laparoscopic technique using a single 2-mm port and a modified Seldinger technique is feasible, safe, and effective for peritoneal dialysis catheter placements.

Для цитирования: Varela J E, Elli E F, Vanuno D, Horgan S. Mini-laparoscopic placement of a peritoneal dialysis catheter.. Surgical endoscopy. 2003. DOI: 10.1007/s00464-003-8114-0.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.