MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jse.2014.08.009

Медицинская библиотека · Journal of shoulder and elbow surgery · 2014

Which parameters affect medium- to long-term results after angular stable plate fixation for proximal humeral fractures?

Bahrs Christian, Kühle Luise, Blumenstock Gunnar, Stöckle Ulrich, Rolauffs Bernd, Freude Thomas

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Very little information on medium- to long-term results is available for surgically treated proximal humeral fractures. The aim of this prospective treatment study was to present long-term results after angular stable plate fixation of displaced proximal humeral fractures and to detect which specific patient- and fracture-related parameters affect the clinical outcome.

METHODS

We performed a prospective clinical and radiologic evaluation of 77 patients with a displaced proximal humeral fracture (28 Neer 2-part, 38 3-part, and 11 4-part fractures; 28 AO A fractures, 30 AO B fractures, and 19 AO C fractures) treated with angular stable plate fixation after a mean follow-up period of 96 months (range, 74-133 months). We assessed outcomes with the Constant, University of California-Los Angeles (UCLA), and Disabilities of the Arm, Shoulder, and Hand (DASH) scores and evaluated specific patient- and fracture-related parameters including complications.

RESULTS

The mean Constant, University of California-Los Angeles (UCLA), and Disabilities of the Arm, Shoulder, and Hand (DASH) scores were 79, 31, and 12 points. Reasons for revisions were implant-related impingement (n = 13), screw perforation (n = 10), infection (n = 4), and secondary fracture displacement (n = 1). There was a significant association between worse score results and occurrence of secondary fracture displacement, screw perforation, residual bone deformities, and a rotator cuff defect at follow-up.

CONCLUSIONS

Good medium- to long-term results after angular stable plate fixation of displaced proximal humeral fracture can be expected. A reconstruction within a range of 15° in both anteroposterior and axillary views and <5-mm tuberosity displacement should be the aim of head-preserving surgery to prevent complications, such as secondary fracture displacement and screw perforation, and a less favorable long-term result.

Для цитирования: Bahrs Christian, Kühle Luise, Blumenstock Gunnar, Stöckle Ulrich, Rolauffs Bernd, Freude Thomas. Which parameters affect medium- to long-term results after angular stable plate fixation for proximal humeral fractures?. Journal of shoulder and elbow surgery. 2014. DOI: 10.1016/j.jse.2014.08.009.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.