Intranasal midazolam as first-line inhospital treatment for status epilepticus: a pharmaco-EEG cohort study.
Аннотация
OBJECTIVE
We sought to evaluate the efficacy and tolerability of intranasal midazolam (in-MDZ) as first-line inhospital therapy in patients with status epilepticus (SE) during continuous EEG recording.
METHODS
Data on medical history, etiology and semiology of SE, anticonvulsive medication usage, efficacy and safety of in-MDZ were retrospectively reviewed between 2015 and 2018. Time to end of SE regarding the administration of in-MDZ and ß-band effects were analyzed on EEG and with frequency analysis.
RESULTS
In total, 42 patients (mean age: 52.7 ± 22.7 years; 23 females) were treated with a median dose of 5 mg of in-MDZ (range: 2.5-15 mg, mean: 6.4 mg, SD: 2.6) for SE. The majority of the patients suffered from nonconvulsive SE (n = 24; 55.8%). In total, 24 (57.1%) patients were responders, as SE stopped following the administration of in-MDZ without any other drugs being given. On average, SE ceased on EEG at 05:05 (minutes:seconds) after the application of in-MDZ (median: 04:56; range: 00:29-14:53; SD:03:13). Frequency analysis showed an increased ß-band on EEG after the application of in-MDZ at 04:07 on average (median: 03:50; range: 02:20-05:40; SD: 01:09). Adverse events were recorded in six patients (14.3%), with nasal irritations present in five (11.9%) and prolonged sedation occurring in one (2.6%) patient.
CONCLUSIONS
This pharmaco-EEG-based study showed that in-MDZ is effective and well-tolerated for the acute treatment of SE. EEG and clinical effects of in-MDZ administration occurred within 04:07 and 5:05 on average. Intranasal midazolam appears to be an easily applicable and rapidly effective alternative to buccal or intramuscular application as first-line treatment if an intravenous route is not available.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.