BACKGROUND

Robot-assisted endoscopic transaxillary thyroidectomy is an emerging surgical technique that needs to be evaluated in European patients. We evaluate the feasibility and preliminary results of our experience of this technique in a cohort of patients from within a single European university hospital (Nîmes, France).

METHODS

We performed a retrospective review of the first 23 patients, treated consecutively between September 2010 and June 2012.

RESULTS

Nine patients underwent total thyroidectomy and 14 patients lobectomies. All procedures were completed successfully with a mean total operative time of 134 min. We observed a single case of internal jugular vein injury during the console time. No instances of persistent complications were observed; however, minor postoperative events occurred in 5 patients. Pathological diagnoses included benign follicular adenoma in 18 patients, benign adenoma with lymphoid thyroiditis in 1 patient, and benign adenoma with Graves' disease in 4 patients.

CONCLUSIONS

Robotic thyroid surgery is feasible in European patients and can be safely performed on selected patients. This technique has infrequent minor complications and provides a high level of satisfaction.

Для цитирования: Lallemant Benjamin, Chambon Guillaume, Galy-Bernadoy Camille, Chapuis Héliette, Guedj Anne-Marie, Pham Huy Trang, Lallemant Jean-Gabriel, Rupp Damien. Transaxillary robotic thyroid surgery: a preliminary European experience.. European thyroid journal. 2013. DOI: 10.1159/000351111.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.