MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1021/acsabm.5c01950

Медицинская библиотека · ACS applied bio materials · 2025

Mask-Free Laser-Defined Nonenzymatic Glucose Biosensors for High-Sensitivity and Durable Monitoring.

Park Su-Jeong, Kim Yumin, Lim Hana, Hwang Taehoon, Tsogbayar Dashdendev, Kim Hyun-Jong, Lee Hwa Sung, Yang Chanwoo

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Reliable and noninvasive monitoring of glucose remains a critical challenge for wearable healthcare devices. Conventional enzymatic sensors, while selective, suffer from limited stability and short operational lifetimes, highlighting the need for robust nonenzymatic alternatives. Here, we report a nonenzymatic, noninvasive glucose biosensor fabricated through the combination of laser irradiation (LI) and electroless plating (ELP). LI of a SnO2/polyurethane acrylate (PUA) composite selectively exposed catalytic sites, enabling uniform Cu/Ni/Au metallization via ELP. The resulting electrodes were well-formed, exhibiting low resistivity (21.94 ± 1.09 mΩ·cm) and strong mechanical stability, maintaining conductivity even after 100,000 folding cycles at a bending radius of 5 mm. Functionalization with catalytic Pt/C endowed the electrodes with high catalytic activity, yielding reliable cyclic voltammetry (CV) responses and superior glucose detection capability. Compared with a commercial electrode, the LI-ELP biosensor achieved nearly 18-fold higher sensitivity (16.3 ± 1.40 vs 0.92 ± 0.10 mA mM-1 cm-2) and improved linearity (0.96 vs 0.94) over the 0-0.5 mM glucose range. The superior performance is attributed to the enlarged active surface area, optimized electrode structure, and efficient catalyst utilization, which collectively reduced overpotentials and enhanced charge-transfer efficiency. Overall, these findings establish LI-ELP as an effective and scalable strategy for fabricating durable, conductive, and efficient electrodes, highlighting its strong potential for next-generation wearable biosensors and broader nonenzymatic electrochemical sensing applications.

Для цитирования: Park Su-Jeong, Kim Yumin, Lim Hana, Hwang Taehoon, Tsogbayar Dashdendev, Kim Hyun-Jong, Lee Hwa Sung, Yang Chanwoo. Mask-Free Laser-Defined Nonenzymatic Glucose Biosensors for High-Sensitivity and Durable Monitoring.. ACS applied bio materials. 2025. DOI: 10.1021/acsabm.5c01950.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.