Safety and efficacy of robotic-assisted versus manual percutaneous coronary intervention: a systematic review and updated meta-analysis.

Ramadhan Roy Novri, Rampengan Derren David Christian Homenta, Willyanto Sebastian Emmanuel, Farahiyah Jihaan, Putra Rendra Mahardhika, Multazam Chaq El Chaq Zamzam, Bermpeis Konstantinos, Alsagaff Mochamad Yusuf, Ariyanto Melissa Valentina, Mustofa Ali

СтатьяСистематический обзорМетаанализПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

INTRODUCTION

Percutaneous coronary intervention (PCI) is a fundamental aspect of coronary artery disease (CAD) management. However, manual PCI (M-PCI) procedures bring potential risks such as long-term radiation exposure, operator fatigue, and injuries, posing a threat of malignancies, orthopedic problems, cataracts, and other medical complications. The recently developed robotic-assisted PCI (R-PCI) system allows PCI to be performed from a protected cockpit, reducing radiation exposure, orthopedic injuries, and contrast media usage and improving stent placement accuracy for patients.

OBJECTIVES

This review aims to assess the safety and efficacy of robotic-assisted PCI.

METHODS

A comprehensive search was conducted across six databases including PubMed, EBSCO, Cochrane (CENTRAL), Scopus, ScienceDirect, and ProQuest, covering studies published from October 2023 to November 2023. The outcomes of interest included safety assessment through (I) procedure-related adverse event rate and (II) mortality rate, while efficacy was assessed through (I) procedural time, (II) fluoroscopy time, (III) contrast volume, (IV) clinical procedural success, and (V) technical success. Quality appraisal was performed using ROBINS-I, and meta-analysis was conducted using RevMan 5.4.

RESULTS

A search across 6 databases resulted in 15 articles for analysis. We found that R-PCI is superior to M-PCI in reducing fluoroscopy time (MD = -3.68, 95% CI = -6.25 to -1.11, p = 0.005) and contrast volume (MD = -16.79, 95% CI = -22.28 to -11.30, p < 0.00001). However, there is no significant difference in terms of procedure-related adverse events, mortality rate, procedural time, and clinical procedural, and technical success.

CONCLUSION

R-PCI offers procedural advantages, particularly in reducing fluoroscopy time and contrast use, while demonstrating comparable safety and efficacy to M-PCI. Further, high-quality trials are needed to clarify its long-term clinical impact.

Для цитирования: Ramadhan Roy Novri, Rampengan Derren David Christian Homenta, Willyanto Sebastian Emmanuel, Farahiyah Jihaan, Putra Rendra Mahardhika, Multazam Chaq El Chaq Zamzam, Bermpeis Konstantinos, Alsagaff Mochamad Yusuf, Ariyanto Melissa Valentina, Mustofa Ali. Safety and efficacy of robotic-assisted versus manual percutaneous coronary intervention: a systematic review and updated meta-analysis.. Systematic reviews. 2025. DOI: 10.1186/s13643-025-02998-7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.