[Determination of phenyl(2-naphthyl)amine concentrations in the working environment air using HPLC-FLD technique].

Jeżewska Anna, Kondej Dorota

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Phenyl(2-naphthyl)amine (FNA) is a flammable solid with a characteristic odor. FNA is used, among others, in the production of paints and dyes, and as an antioxidant in rubber processing, lubricant for automobile engines, in brake fluids, oils, etc. In the European Union, FNA is classified as a category 2 carcinogen. In Poland, the value of the maximum admissible concentration (MAC) for FNA is 0.02 mg/m3. The aim of this study was to develop a new method for the determination of FNA, which will allow for the determination of this substance in the working environment within the concentration range of 0.1-2 of MAC value.

MATERIAL AND

METHODS

The method is based on the retention of FNA on a cellulose filter, recovery of the substance with methanol and analysis of the solution thus obtained using a high-performance liquid chromatograph with a fluorescence detector.

RESULTS

The developed method enables the determination of FNA in the concentration range 2-40 μg/m3. The limit of detection (LOD) is 0.23 ng/l and the limit of quantification (LOQ) is 0.69 ng/l.

CONCLUSIONS

The method complies with the requirements of the European Standard PN-EN 482 and can be used to determine FNA concentrations in the workplaces air. Med Pr. 2022;73(1):25-31.

Для цитирования: Jeżewska Anna, Kondej Dorota. [Determination of phenyl(2-naphthyl)amine concentrations in the working environment air using HPLC-FLD technique].. Medycyna pracy. 2022. DOI: 10.13075/mp.5893.01152.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.