MedElevator Войти в исследования
← Поиск публикаций
Медицинская библиотека · Peritoneal dialysis international : journal of the International Society for Peritoneal Dialysis · 1999

The self-locating catheter: clinical evaluation and comparison with the Tenckhoff catheter.

Cavagna R, Tessarin C, Tarroni G, Casol D, De Silvestro L, Fabbian F

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

BACKGROUND

Peritoneal catheter displacement appears to be related to various causes including omental attachment, bowel contractions, peritoneal adhesions, and the catheter floating in the dialysis fluid. In order to prevent this complication, which can impair peritoneal dialysis efficacy, Di Paolo et al. designed a "self-locating catheter" (SLC) that is similar to the Tenckhoff catheter (TC) and includes a small tungsten cylinder (weight 12 g) at the distal end (Di Paolo N, et al. The self positioning catheter. Proceedings of the VII Italian Congress on Peritoneal Dialysis. Milan: Wichtig Editore, 1993:539-42). The weight of the tip prevents the catheter from floating and migrating by gravitation toward the Douglas cavity.

OBJECTIVE

Starting in 1996, we implanted SLC in 15 continuous ambulatory peritoneal dialysis patients. The aim of our study was to compare the ratio of migration and other catheter-related complications between patients with SLC (196 patient-months) and 13 patients with conventional straight TC (295 patient-months).

RESULTS

Peritonitis ratio, catheter complication rate, dialysate inflow and outflow, and weekly creatinine clearance were similar in the two groups of patients. The incidence of catheter displacement was significantly higher (p = 0.0349) in theTC group than in the SLC group (4 vs 0).

CONCLUSION

In our experience, the SLC seems to be useful in preventing catheter migration by continuous gravitation of its extremity toward the pelvic cavity.

Для цитирования: Cavagna R, Tessarin C, Tarroni G, Casol D, De Silvestro L, Fabbian F. The self-locating catheter: clinical evaluation and comparison with the Tenckhoff catheter.. Peritoneal dialysis international : journal of the International Society for Peritoneal Dialysis. 1999.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.