Late-Onset Suspected Coronary Vasospasm Following Focal Monopolar Pulsed-Field Ablation for Atrial Fibrillation.
Аннотация
INTRODUCTION
Coronary vasospasm is a recognized complication of pulsed-field ablation (PFA), but delayed events are rarely described.
METHODS AND
RESULTS
A 64-year-old man underwent atrial fibrillation ablation using a focal monopolar PFA catheter. He developed transient chest discomfort 18 h after ablation, followed by sustained chest tightness with ST-segment depression 42 h post-procedure. Symptoms and electrocardiographic changes resolved promptly with sublingual nitroglycerin, suggesting coronary vasospasm.
CONCLUSION
Coronary vasospasm after focal monopolar PFA may occur beyond the immediate post-procedural period, which may have implications for monitoring and discharge planning.