MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/paf.0000000000000996

Медицинская библиотека · The American journal of forensic medicine and pathology · 2024

A Rare Case of Neonatal Death Due to a Cranial Vault Fracture Following the Use of Obstetric Vacuum Extractor and Review of Literature.

Caputo Fiorella, Caristo Isabella, Barranco Rosario, Vallega Bernucci Luca, Torielli Flaminia, Ventura Francesco

СтатьяКлинический случайОбзорПеревод в очереди

Аннотация

In the course of childbirth, if complications arise during the expulsion of the fetus, instruments can be employed to facilitate delivery. The vacuum extractor, or ventouse, is considered a relatively safe tool associated with a low rate of complications and mortality. However, it is crucial that the instrument be applied in the correct position and that the pulling force is not excessive to minimize damage to the fetal cranial structures. Fractures of the cranial vault following the application of obstetric vacuum extraction are very rare events.This paper presents a case of perinatal death due to cranial vault fracture and subgaleal hematoma following vacuum extractor application. Only through postmortem examination was it possible to identify incorrect positioning of the ventouse, which was lateralized compared to the recommended position. The misplacement of the device led to an imbalance of forces, causing the cranial vault fracture that led to the infant's demise.A thorough postmortem examination is essential in cases of perinatal death resulting from operative delivery to ascertain the cause of death and reconstruct the dynamics of events during childbirth. In particular, the examination of injuries on the decedent neonate may reveal improper positioning of the instrument.

Для цитирования: Caputo Fiorella, Caristo Isabella, Barranco Rosario, Vallega Bernucci Luca, Torielli Flaminia, Ventura Francesco. A Rare Case of Neonatal Death Due to a Cranial Vault Fracture Following the Use of Obstetric Vacuum Extractor and Review of Literature.. The American journal of forensic medicine and pathology. 2024. DOI: 10.1097/paf.0000000000000996.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.