Hydrogen peroxide-enhanced three-dimensional endoanal ultrasonography and endoanal magnetic resonance imaging in evaluating perianal fistulas: agreement and patient preference.

West Rachel L, Dwarkasing Soendersing, Felt-Bersma Richelle J F, Schouten W Ruud, Hop Wim C J, Hussain Shahid M, Kuipers Ernst J

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVES

To determine agreement between hydrogen peroxide-enhanced three-dimensional endoanal ultrasonography (3D HPUS) and endoanal magnetic resonance imaging (MRI) in preoperative assessment of perianal fistulas, and to assess patient preference with regard to these techniques.

METHODS

Forty patients (31 males, aged 21-70 years) with symptoms of a perianal fistula and a visible external opening underwent preoperative 3D HPUS and endoanal MRI. The results were assessed separately by experienced observers. Fistulas were described according to the following characteristics: classification of the primary fistula tract according to Parks, location of the internal opening, presence of secondary tracts and fluid collections. Patients were asked to score the amount of discomfort experienced during both procedures and express their preference for either method.

RESULTS

The median time interval between 3D HPUS and endoanal MRI was 14 days (range, 0-91 days). The methods agreed in 88% (35/40, kappa = 0.45) for the primary fistula tract, in 90% (36/40, kappa = 0.83) for the location of the internal opening, in 78% (31/40, kappa = 0.62) for secondary tracts, and in 88% (35/40, kappa = 0.63) for fluid collections. Both methods were associated with similar discomfort, and there was no patient preference for one procedure over the other.

CONCLUSIONS

3D HPUS and endoanal MRI are equally adequate for the evaluation of perianal fistulas. Both methods are associated with similar discomfort and patients have no preference for either procedure.

Для цитирования: West Rachel L, Dwarkasing Soendersing, Felt-Bersma Richelle J F, Schouten W Ruud, Hop Wim C J, Hussain Shahid M, Kuipers Ernst J. Hydrogen peroxide-enhanced three-dimensional endoanal ultrasonography and endoanal magnetic resonance imaging in evaluating perianal fistulas: agreement and patient preference.. European journal of gastroenterology & hepatology. 2004. DOI: 10.1097/00042737-200412000-00014.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.