Impedimetric sensing of C-reactive protein using a novel molecularly imprinted polymer coupled with bismuth-enhanced cobalt ferrite nanocomposites for cardiovascular risk assessment.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Singh Siddhima, Singh Astha, Singh Neelottma, Singh Jay

Аннотация

This study reports an approach of using a molecularly imprinted polymer (MIP) combined with Bi-doped cobalt ferrite (BixCoFe2O4) nanoparticles (NPs) for detecting C-reactive protein (CRP), a marker associated with cardiovascular diseases (CVDs). Sudden cardiac arrest is a growing concern in India, where CVDs have become the leading cause of mortality. MIPs have recently drawn increasing interest over time; consequently, the objective of this study is to engineer an MIP-based electrochemical sensor due to their reliability, ease of electrochemical control for template removal, and cavity renewal. MIPs are selective polymers that can bind target molecules and are synthesised using a ratio of 1 : 4 : 20 of a novel functional monomer (4-nitrophenyl methacrylate), a template (CRP), and a crosslinker (EGDMA) via the bulk polymerisation method, along with BixCoFe2O4 NPs (Bi = 0.05, 0.10, 0.15, and 0.20 M). These NPs and MIPs were characterised using powder X-ray diffraction (XRD), Fourier transform infrared (FTIR) spectroscopy, field emission scanning electron microscopy (FE-SEM), high-resolution transmission electron microscopy (HR-TEM), energy dispersive X-ray (EDX) analysis, dynamic light scattering (DLS), ultraviolet-visible (UV) spectroscopy, X-ray photoelectron spectroscopy (XPS), atomic force microscopy (AFM), and the Brunauer-Emmett-Teller (BET) method. The synthesised NPs and MIP were fabricated onto an indium tin oxide (ITO) electrode using the electrophoretic deposition (EPD) process. Moreover, an electrochemical analysis was conducted using voltammetry and electrochemical impedance sensing (EIS) techniques for CRP detection across two linear ranges: a lower range of 0.5-80 ng mL-1 with a limit of detection (LOD) of 0.1609 ng mL-1 and a sensitivity of 0.740 Ω ng-1 cm-2, and a higher range of 90-400 ng mL-1, in which the LOD was 0.3262 ng mL-1, sensitivity was 0.0631 Ω ng-1 cm-2 and the response time of the fabricated sensor was observed to be 10 seconds.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты