MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.arth.2023.10.050

Медицинская библиотека · The Journal of arthroplasty · 2023

Intraincisional Pin Placement is Safe for Robotic-Assisted Total Knee Arthroplasty.

Stetzer Michael, Bircher James, Klika Alison K, Rullán Pedro J, Bloomfield Michael M, Krebs Viktor E, Molloy Robert M, Piuzzi Nicolas S

СтатьяПеревод в очереди

Аннотация

BACKGROUND

While robotic-arm assisted total knee arthroplasty (RA-TKA) has seen a major increase in its utilization, it requires bone array pins to be fixed into the femur and tibia, which intrinsically carries a risk. As it is currently off-label with some robotic platforms to place pins intraincisional, we aimed to evaluate the safety of intraincisional pin placement during RA-TKAs.

METHODS

A prospective cohort of 2,343 patients who underwent RA-TKA at a North American Healthcare System between January 2018 and March 2022 was included. Primary outcomes included periprosthetic fracture or infection (eg, superficial or deep). Secondary outcomes included 1-year reoperation rate due to any cause. Cases were retrospectively reviewed to determine whether complications could be attributed to metaphyseal intraincisional pin placement (4.0 mm pins; two tibial and two femoral). The 90-day follow-up was 100% and the 1-year follow-up rate was 70.6% (n = 1,655).

RESULTS

The pin-site related periprosthetic fracture incidence at 90 days was 0.09% (2 out of 2,343). The 90-day infection incidence was 1.4% (superficial: 22; deep: 13). The 1-year reoperation rate was 1.8% (29 out of 1,655). The most common causes of reoperation at 1-year were deep infection (n = 14; 0.83%), superficial infection (n = 3; 0.18%), periprosthetic fracture, mechanical symptoms, instability, and hematoma (n = 2; 0.12% for each).

CONCLUSIONS

One in 1,172 patients may experience a pin-related periprosthetic fracture after RA-TKA with intraincisional bone array pin placement. There was a low 90-day infection incidence and reoperations within 1-year after RA-TKA were rare.

Для цитирования: Stetzer Michael, Bircher James, Klika Alison K, Rullán Pedro J, Bloomfield Michael M, Krebs Viktor E, Molloy Robert M, Piuzzi Nicolas S. Intraincisional Pin Placement is Safe for Robotic-Assisted Total Knee Arthroplasty.. The Journal of arthroplasty. 2023. DOI: 10.1016/j.arth.2023.10.050.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.