MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1080/14767058.2018.1517324

Медицинская библиотека · The journal of maternal-fetal & neonatal medicine : the official journal of the European Association of Perinatal Medicine, the Federation of Asia and Oceania Perinatal Societies, the International Society of Perinatal Obstetricians · 2018

Uterocervical angle: an ultrasound screening tool to predict satisfactory response to labor induction.

Eser Ahmet, Ozkaya Enis

Оценочное исследованиеСтатьяПеревод в очереди

Аннотация

Background

A wide uterocervical angle >95° detected during the second trimester was associated with an increased risk for spontaneous preterm birth.

Objective

We aimed to determine whether an ultrasonographic marker, uterocervical angle, correlates with satisfactory response to labor induction.Study design: We conducted a prospective cohort study from May 2016 through December 2017 of singleton term gestations undergoing transvaginal ultrasound for cervical length screening and uterocervical angle measurement. Uterocervical angle was measured between the lower uterine segment and the cervical canal. Latent phase duration >720 min was accepted to be a prolonged latent phase. The primary outcome was a prediction of satisfactory response to labor induction (latent phase duration <720 min).

Results

Both anterior uterocervical angle (AUC = 0.802, p < .001) and the cervical length (AUC = 0.679, p < .05) significantly predicted satisfactory response to labor induction. Optimal cutoff value was obtained at the value of 97° (64% sensitivity, 91% specificity) for anterior uterocervical angle and 27 mm (64% sensitivity, 64% specificity) for the cervical length. Kaplan-Meier survival analysis showed that duration from labor induction to delivery was significantly higher in a group with longer cervical length (p = .04), additionally labor induction to delivery time was significantly higher in a group with lower UCA (p = .04).

Conclusions

Both the cervical length and anterior uterocervical length were predictors for the satisfactory response to labor induction, and both parameters were found to be significantly associated with time from induction to delivery in survival analysis.

Для цитирования: Eser Ahmet, Ozkaya Enis. Uterocervical angle: an ultrasound screening tool to predict satisfactory response to labor induction.. The journal of maternal-fetal & neonatal medicine : the official journal of the European Association of Perinatal Medicine, the Federation of Asia and Oceania Perinatal Societies, the International Society of Perinatal Obstetricians. 2018. DOI: 10.1080/14767058.2018.1517324.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.