MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/jat/bkw011

Медицинская библиотека · Journal of analytical toxicology · 2016

Simultaneous Measurement of 3-Chlorotyrosine and 3,5-Dichlorotyrosine in Whole Blood, Serum and Plasma by Isotope Dilution HPLC-MS-MS.

Crow Brian S, Quiñones-González Jennifer, Pantazides Brooke G, Perez Jonas W, Winkeljohn W Rucks, Garton Joshua W, Thomas Jerry D, Blake Thomas A, Johnson Rudolph C

СтатьяПоддержка исследования: вне правительства СШАПоддержка службы здравоохранения СШАПеревод в очереди

Аннотация

Chlorine is a public health concern and potential threat due to its high reactivity, ease and scale of production, widespread industrial use, bulk transportation, massive stockpiles and history as a chemical weapon. This work describes a new, sensitive and rapid stable isotope dilution method for the retrospective detection and quantitation of two chlorine adducts. The biomarkers 3-chlorotyrosine (Cl-Tyr) and 3,5-dichlorotyrosine (Cl2-Tyr) were isolated from the pronase digest of chlorine exposed whole blood, serum or plasma by solid-phase extraction (SPE), separated by reversed-phase HPLC and detected by tandem mass spectrometry (MS-MS). The calibration range is 2.50-1,000 ng/mL (R2 ≥ 0.998) with a lowest reportable limit (LRL) of 2.50 ng/mL for both analytes, an accuracy of ≥93% and an LOD of 0.443 ng/mL for Cl-Tyr and 0.396 ng/mL for Cl2-Tyr. Inter- and intra-day precision of quality control samples had coefficients of variation of ≤10% and ≤7.0%, respectively. Blood and serum samples from 200 healthy individuals and 175 individuals with chronic inflammatory disease were analyzed using this method to assess background levels of chlorinated tyrosine adducts. Results from patients with no known inflammatory disease history (healthy) showed baseline levels of <LRL-4.26 ng/mL Cl-Tyr and <LRL Cl2-Tyr. Patients with inflammatory disease had baseline levels of <LRL-15.4 ng/mL Cl-Tyr and <LRL-5.22 ng/mL Cl2-Tyr. Blood exposed to 2.02 ppm chlorine gas for 15 min produced 941 ng/mL Cl-Tyr and 223 ng/mL Cl2-Tyr. This high-throughput method has been developed and analytically validated for the diagnosis of human exposure to chlorine.

Для цитирования: Crow Brian S, Quiñones-González Jennifer, Pantazides Brooke G, Perez Jonas W, Winkeljohn W Rucks, Garton Joshua W, Thomas Jerry D, Blake Thomas A, Johnson Rudolph C. Simultaneous Measurement of 3-Chlorotyrosine and 3,5-Dichlorotyrosine in Whole Blood, Serum and Plasma by Isotope Dilution HPLC-MS-MS.. Journal of analytical toxicology. 2016. DOI: 10.1093/jat/bkw011.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.