MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/ico.0000000000001229

Медицинская библиотека · Cornea · 2017

Comparison of 2 Different Methods of Transepithelial Corneal Collagen Cross-Linking: Analysis of Corneal Histology and Hysteresis.

Park Young Min, Kim Ho Yoon, Lee Jong Soo

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

PURPOSE: To compare the effect of 2 different methods of transepithelial corneal collagen cross-linking (CXL) on corneal histology and hysteresis.

METHODS

The right eyes of New Zealand white rabbits (n = 50) were treated using one of the 2 transepithelial CXL methods. The eyes were then divided into 2 groups: group 1, transepithelial CXL using continuous ultraviolet A (UVA); group 2, accelerated transepithelial CXL using pulsed UVA.

RESULTS

Both groups showed a postoperative increase in central corneal thickness. In both groups, an increase in corneal hysteresis was found after CXL, but the changes were not significant when compared with the baseline value. The corneal resistance factor and corneal-compensated intraocular pressure also remained unchanged in both groups after treatment. In both groups, the CXL effect reached the anterior-mid part of the corneal stroma. In group 1, CXL mostly affected the anterior-mid part stroma, whereas group 2 showed stromal keratocyte loss, and an acellular zone, in the deep stroma. More signs of keratocyte apoptosis were observed in group 2 than in group 1.

CONCLUSIONS

Accelerated transepithelial CXL using pulsed UVA showed considerably deeper effect in the stroma with keratocyte loss than transepithelial CXL using continuous UVA.

Для цитирования: Park Young Min, Kim Ho Yoon, Lee Jong Soo. Comparison of 2 Different Methods of Transepithelial Corneal Collagen Cross-Linking: Analysis of Corneal Histology and Hysteresis.. Cornea. 2017. DOI: 10.1097/ico.0000000000001229.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.