MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/nau.23582

Медицинская библиотека · Neurourology and urodynamics · 2018

Test-retest reliability of clitoral blood flow measurements using color Doppler ultrasonography at rest and after a pelvic floor contraction task in healthy adult women.

Mercier Joanie, Tang An, Morin Mélanie, Khalifé Samir, Lemieux Marie-Claude, Reichetzer Barbara, Dumoulin Chantale

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

AIMS: Test-retest reliability assessment of the dorsal clitoral artery's blood flow at rest and after muscle activation has never been documented. If this outcome measure is to be used in conditions impeding vascularity, it requires a psychometric evaluation. The aim of this study was to assess the inter-session test-retest reliability of clitoral blood flow in healthy women using color Doppler ultrasonography at rest and after a pelvic floor muscle (PFM) contraction task.

METHODS

Two assessment sessions were conducted using a clinical ultrasound system. Clitoral blood flow measurements were repeated at rest and after a PFM contraction task. Measurements of the peak systolic velocity (PSV), time-averaged maximum velocity (TAMX), end-diastolic velocity (EDV), pulsatility index (PI), and resistance index (RI) were taken. The test-retest reliability was assessed using paired t-test, intraclass correlation coefficient (ICC), and Bland-Altman plots.

RESULTS

For reliability at rest, ICC values were 0.95 for PSV, 0.87 for TAMX, and 0.67 for both PI and RI. The variability between measurements, as per Bland-Altman plots, was small for PSV, TAMX, and RI and acceptable for PI. For reliability after the PFM contractions task, ICC values were 0.85 for PSV, 0.77 for TAMX, 0.79 for PI, and 0.81 for RI. The variability between measurements was small for PSV and RI and acceptable for TAMX and PI. EDV parameter did not perform as well in both conditions.

CONCLUSIONS

Assessment of the clitoral blood flow with color Doppler ultrasound is reliable at rest and after a PFM contraction task.

Для цитирования: Mercier Joanie, Tang An, Morin Mélanie, Khalifé Samir, Lemieux Marie-Claude, Reichetzer Barbara, Dumoulin Chantale. Test-retest reliability of clitoral blood flow measurements using color Doppler ultrasonography at rest and after a pelvic floor contraction task in healthy adult women.. Neurourology and urodynamics. 2018. DOI: 10.1002/nau.23582.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.