DOI 10.1159/000369120

Медицинская библиотека · Neonatology · 2015

Laryngeal muscle activity during nasal high-frequency oscillatory ventilation in nonsedated newborn lambs.

Hadj-Ahmed Mohamed Amine, Samson Nathalie, Nadeau Charlène, Boudaa Nadia, Praud Jean-Paul

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

We have previously shown that nasal pressure support ventilation (nPSV) can lead to an active inspiratory laryngeal narrowing in lambs. This, in turn, can limit lung ventilation and divert air into the digestive system, with potentially deleterious consequences. On the other hand, nasal high-frequency oscillatory ventilation (nHFOV) is particularly attractive in newborns, especially since, unlike nPSV, it does not require synchronization with the patient's inspiratory efforts.

OBJECTIVES

The main aim of the present study was to test the hypothesis that glottal constrictor muscle activity (EMG) does not develop during nHFOV. A secondary objective was to study laryngeal EMG during nHFOV-induced central apneas.

METHODS

Polysomnographic recordings were performed in 7 nonsedated lambs which were ventilated with increasing levels of nPSV and nHFOV at both 4 and 8 Hz, in random order. States of alertness, diaphragm and glottal muscle EMG, SpO2, and respiratory movements were continuously recorded.

RESULTS

While phasic inspiratory glottal constrictor EMG appeared with increasing nPSV levels in 6 out of 7 lambs, it was never observed with nHFOV. In addition, nHFOV at 4 Hz dramatically inhibited central respiratory drive in 4/7 lambs, with 64-100% of recording time spent in central apnea in 3 lambs. No glottal constrictor EMG was observed during these central apneas.

CONCLUSION

nHFOV does not induce glottal constrictor muscle EMG in nonsedated newborn lambs, in contrast to nPSV. This may be an additional advantage of nHFOV relative to nPSV.

Для цитирования: Hadj-Ahmed Mohamed Amine, Samson Nathalie, Nadeau Charlène, Boudaa Nadia, Praud Jean-Paul. Laryngeal muscle activity during nasal high-frequency oscillatory ventilation in nonsedated newborn lambs.. Neonatology. 2015. DOI: 10.1159/000369120.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.