Phrenic nerve neurotization utilizing the spinal accessory nerve: technical note with potential application in patients with high cervical quadriplegia.
Аннотация
INTRODUCTION
High cervical quadriplegia is associated with high morbidity and mortality. Artificial respiration in these patients carries significant long-term risks such as infection, atelectasis, and respiratory failure. As phrenic nerve pacing has been proven to free many of these patients from ventilatory dependency, we hypothesized that neurotization of the phrenic nerve with the spinal accessory nerve (SAN) may offer one potential alternative to phrenic nerve stimulation via pacing and may be more efficacious and longer lasting without the complications of an implantable device.
MATERIALS AND
METHODS
Ten cadavers (20 sides) underwent exposure of the cervical phrenic nerve and the SAN in the posterior cervical triangle. The SAN was split into anterior and posterior halves and the anterior half transposed to the ipsilateral phrenic nerve as it crossed the anterior scalene muscle.
RESULTS
The mean distance between the cervical phrenic nerve and the SAN in the posterior cervical triangle was 2.5 cm proximally, 4 cm at a midpoint, and 6 cm distally. The range for these measurements was 2 to 4 cm, 3.5 to 5 cm, and 4 to 8.5 cm, respectively. The mean excess length of SAN available after transposition to the more anteromedially placed phrenic nerve was 5 cm (range 4 to 6.5 cm). The mean diameter of these regional parts of the spinal accessory and phrenic nerves was 2 and 2.5 mm, respectively. No statistically significant difference was found for measurements between sides.
CONCLUSIONS
To our knowledge, using the SAN for neurotization to the phrenic nerve for potential use in patients with spinal cord injury has not been previously explored. Following clinical trials, these data may provide a mechanism for self stimulation of the diaphragm and obviate phrenic nerve pacing in patients with high cervical quadriplegia. Our study found that such a maneuver is technically feasible in the cadaver.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.