MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1117/1.jmi.5.2.026001

Медицинская библиотека · Journal of medical imaging (Bellingham, Wash.) · 2018

Quantitative 3-D head ultrasound measurements of ventricle volume to determine thresholds for preterm neonates requiring interventional therapies following posthemorrhagic ventricle dilatation.

Kishimoto Jessica, Fenster Aaron, Lee David S C, de Ribaupierre Sandrine

СтатьяПеревод в очереди

Аннотация

Dilatation of the cerebral ventricles is a common condition in preterm neonates with intraventricular hemorrhage. This posthemorrhagic ventricle dilatation (PHVD) can lead to lifelong neurological impairment through ischemic injury due to increased intracranial pressure, and without treatment can lead to death. Two-dimensional ultrasound (US) through the fontanelles of the patients is serially acquired to monitor the progression of PHVD. These images are used in conjunction with clinical experience and physical exams to determine when interventional therapies such as needle aspiration of the built up cerebrospinal fluid (ventricle tap, VT) might be indicated for a patient; however, quantitative measurements of the ventricles size are often not performed. We describe the potential utility of the quantitative three-dimensional (3-D) US measurements of ventricle volumes (VVs) in 38 preterm neonates to monitor and manage PHVD. Specifically, we determined 3-D US VV thresholds for patients who received VT in comparison to patients with PHVD who resolve without intervention. In addition, since many patients who have an initial VT will receive subsequent interventions, we determined which PHVD patients will receive additional VT after the initial one has been performed.

Для цитирования: Kishimoto Jessica, Fenster Aaron, Lee David S C, de Ribaupierre Sandrine. Quantitative 3-D head ultrasound measurements of ventricle volume to determine thresholds for preterm neonates requiring interventional therapies following posthemorrhagic ventricle dilatation.. Journal of medical imaging (Bellingham, Wash.). 2018. DOI: 10.1117/1.jmi.5.2.026001.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.