Application of High-Frequency Oscillation Ventilation Combined With Volume Guarantee in Preterm Infants With Acute Hypoxic Respiratory Failure After Patent Ductus Arteriosus Ligation.
Аннотация
OBJECTIVE
This study aimed to evaluate the efficacy and safety of high-frequency oscillation ventilation combined with volume guarantee (HFOV-VG) in preterm infants with acute hypoxemic respiratory failure (AHRF) after patent ductus arteriosus ligation.
METHODS
We retrospectively analyzed the clinical data of 41 preterm infants, who were ventilated for AHRF after patent ductus arteriosus ligation between January 2020 and January 2022. HFOV alone was used in 20 of the 41 infants, whereas HFOV-VG was used in the other 21 infants.
RESULTS
There was no statistically significant difference in the demographic information and baseline characteristics of preterm infants included in the study. The average frequency tidal volume (VThf) of the HFOV-VG group was lower than that of the HFOV group (2.6 ± 0.6 mL versus 1.9 ± 0.3 mL, P < .001). In addition, the incidence of hypocapnia and hypercapnia in infants supported with HFOV-VG was significantly lower (15 versus 8, P < .001; 12 versus 5, P < .001). Furthermore, the duration of invasive ventilation in the HFOV-VG group also was lower than in the HFOV group (3.7 ± 1.2 days versus 2.1 ± 1.0 days, P < .01).
CONCLUSION
Compared with HFOV alone, HFOV-VG decreases VThf levels and reduces the incidence of hypercapnia and hypocapnia in preterm infants with acute hypoxic respiratory failure after patent ductus arteriosus ligation.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.