The Predictors and Outcomes of Early Noninvasive Positive Pressure Ventilation Failure in Very Preterm Infants: A Prospective Study.
Аннотация
Limited data exist on predicting nasal intermittent positive pressure ventilation (NIPPV) failure in very preterm infants. This study aimed to identify factors predicting NIPPV failure, focusing on the fraction of inspired oxygen (FiO2), and evaluating associated outcomes.This prospective observational study included infants with gestational ages between 230/7 and 316/7 weeks, who were managed with NIPPV as the initial respiratory support. Infants were categorized as either successfully managed with NIPPV (NIPPV-S) or failed and required intubation within the first 72 hours of life (NIPPV-F). Predictors of NIPPV failure and clinical outcomes were evaluated. ROC curve analysis was used to determine FiO2 thresholds in the first and second hours of life. Demographic, perinatal, and respiratory parameters were analyzed using univariate and multivariate logistic regression models.Of the 397 infants, 121 (30.5%) failed NIPPV and required intubation. Multivariate analysis revealed that FiO2 in the first hour, FiO2 in the second hour, and mean airway pressure were independent predictors of NIPPV failure. The optimal FiO2 threshold was 0.32 (sensitivity, 79% and specificity, 50%) for the first hour and 0.31 (sensitivity, 75% and specificity, 55%) for the second hour of life. NIPPV failure was associated with an increased risk of pneumothorax (adjusted odds ratio [aOR]: 16.83; 95% confidence interval [CI]: 2.05-138.45; p < 0.001), BPD (aOR: 2.61; 95% CI: 1.47-4.62; p < 0.001), and mortality (aOR: 2.37; 95% CI: 1.32-4.23; p < 0.001).FiO2 is a valuable predictor of NIPPV success in the early hours of life. NIPPV failure, predicted by a FiO2 exceeding 0.30 within the first 2 hours of life, is associated with adverse neonatal outcomes. · FiO2 > 0.30 in first 2 hours predicts NIPPV failure in very preterm infants.. · Early NIPPV failure is linked to increased risks of BPD, pneumothorax, and death.. · FiO2 and MAP are independent predictors of NIPPV failure..
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.