MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1136/bjophthalmol-2016-309363

Медицинская библиотека · The British journal of ophthalmology · 2017

Comparison of corneal endothelial cell density and morphology after posterior chamber phakic intraocular lens implantation with and without a central hole.

Goukon Hiroyasu, Kamiya Kazutaka, Shimizu Kimiya, Igarashi Akihito

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

AIM: To compare the corneal endothelial cells after posterior chamber phakic intraocular lens with and without a central hole (hole implantable collamer lens (ICL) and conventional ICL) implantation for the correction of moderate to high myopia.

METHODS

This retrospective study evaluated 34 eyes of 34 patients who underwent hole ICL implantation and 25 eyes of 25 patients who underwent conventional ICL implantation. Preoperatively and 3 months, and 1 and 2 years postoperatively, we compared the central corneal endothelial cell density (ECD), coefficient of variation in cell size (CV) and the percentage of hexagonal cells (HEX) between the two groups using a non-contact specular microscope (EM-3000, Tomey). Preoperatively and 2 years postoperatively, we also compared them in the peripheral regions.

RESULTS

The mean central ECD loss was 0.3% and 1.1%, 2 years after hole ICL and conventional ICL implantation, respectively (Mann-Whitney U test, p=0.72). There were no significant changes in central ECD, CV or HEX at any time points either after hole ICL or conventional ICL implantation, and a significant decrease only in terms of ECD in the superior regions after conventional ICL implantation.

CONCLUSIONS

Both ICLs do not induce a significant change in the density, polymegethism or polymorphism of corneal endothelial cells even 2 years postoperatively, except for the density in the superior regions after conventional ICL implantation. However, hole ICL implantation may have advantages over conventional ICL implantation only in terms of the density in the superior regions, possibly because preoperative laser iridotomies are unnecessary.

Для цитирования: Goukon Hiroyasu, Kamiya Kazutaka, Shimizu Kimiya, Igarashi Akihito. Comparison of corneal endothelial cell density and morphology after posterior chamber phakic intraocular lens implantation with and without a central hole.. The British journal of ophthalmology. 2017. DOI: 10.1136/bjophthalmol-2016-309363.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление