MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4293/108680810x12924466009168

Медицинская библиотека · JSLS : Journal of the Society of Laparoendoscopic Surgeons · 2011

Bilateral hand-assisted laparoscopic renal surgery in the supine position: the spleen at risk.

Brown James A, Siddiqi Kashif

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

We evaluated the safety of simultaneous bilateral renal procedures performed using hand-assisted laparoscopy (HAL) with the patient in the supine position.

MATERIALS AND

METHODS

After securely strapping the patient to the table, a hand-port device is placed via a 7-cm supraumbilical or peri-umbilical incision with two to four 5-mm to 12-mm trocars placed bilaterally. During a 3-year period, 8 bilateral HAL renal operations were initiated (upper pole partial nephrectomies, 3 nephroureterectomies, 3 bilateral nephrectomies, and right nephrectomy with left adrenalectomy).

RESULTS

Mean patient age was 41 years. One patient with ADPKD required conversion to open due to failure to progress secondary to excessive perirenal fat and 22-cm kidneys. The other 7 were completed successfully with a mean operative time of 417 minutes and mean EBL of 336cc. Two patients received transfusions. Two small splenic lacerations, managed conservatively, were the only complications.

CONCLUSIONS

Bilateral hand-assisted laparoscopic renal surgery with the patient in the supine position (rolling the table side to side) is feasible in the majority of patients. However, very large kidneys (eg, ADPKD) may be better approached with the patient in the lateral decubitus position or via an open subcostal incision. Importantly, the spleen appears to be at increased risk for capsular injury due to apparent increased difficulty of left colon mobilization in the "rolled" or "airplaned" supine position.

Для цитирования: Brown James A, Siddiqi Kashif. Bilateral hand-assisted laparoscopic renal surgery in the supine position: the spleen at risk.. JSLS : Journal of the Society of Laparoendoscopic Surgeons. 2011. DOI: 10.4293/108680810x12924466009168.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.