MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1053/j.jvca.2026.07.027

Медицинская библиотека · Journal of cardiothoracic and vascular anesthesia · 2026

Quantitative Validation of a Simplified 4-Lead Electroencephalogram Montage for Neuromonitoring in Post-Cardiac Surgery Intensive Care Unit Patients.

Shi Zhengsong, Li Ming, Li Hongguang, Wang Qianlin, Yingying Yang, Wang Fang, Chen Huan, Long Yun, Xue Yuechuan

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

Neurologic complications after cardiac surgery are common and associated with high morbidity and mortality. Continuous electroencephalography (cEEG) provides the reference standard for brain monitoring, but the standard 19-lead setup is difficult to implement routinely in the intensive care unit (ICU). Simplified EEG montages derived from high-density recordings were computationally evaluated to identify a configuration that preserves quantitative EEG (qEEG) fidelity for global brain state trend assessment at the bedside.

DESIGN

A retrospective, observational validation study.

SETTING

Single-center cardiac surgical ICU.

PARTICIPANTS

Twenty-six patients admitted to the ICU for at least 24 hours following cardiac surgery with cardiopulmonary bypass, all under deep sedation (Richmond Agitation-Sedation Scale -4) during EEG recording.

INTERVENTIONS: Computational extraction of reduced-lead configurations (2-lead, three 4-lead combinations, and 6-lead) from 16-lead reference EEG recordings.

MEASUREMENTS AND MAIN

RESULTS

Both 4-lead and 6-lead configurations showed good to excellent agreement with the reference. The 4-lead F3+F4+F7+F8 montage achieved excellent reliability intraclass coefficient (>0.9) for 9 of 10 qEEG parameters, with performance comparable to the 6-lead configuration. Bland-Altman analysis showed small bias and acceptable 95% limits of agreement for key parameters.

CONCLUSIONS

A computationally derived 4-electrode montage (F3, F4, F7, and F8) demonstrates close agreement with the 16-electrode reference for global qEEG trend parameters in deeply sedated post-cardiac surgery patients. These findings provide a computational basis for designing a future standalone reduced-electrode acquisition system. Prospective validation with independent hardware is required before clinical deployment, and diagnostic performance for focal events remains to be established.

Для цитирования: Shi Zhengsong, Li Ming, Li Hongguang, Wang Qianlin, Yingying Yang, Wang Fang, Chen Huan, Long Yun, Xue Yuechuan. Quantitative Validation of a Simplified 4-Lead Electroencephalogram Montage for Neuromonitoring in Post-Cardiac Surgery Intensive Care Unit Patients.. Journal of cardiothoracic and vascular anesthesia. 2026. DOI: 10.1053/j.jvca.2026.07.027.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.