MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.arthro.2020.08.003

Медицинская библиотека · Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association · 2020

Arthroscopic Repair of Medium to Large Rotator Cuff Tears With a Triple-Loaded Medially Based Single-Row Technique Augmented With Marrow Vents.

Dierckman Brian D, Frousiakis Petros, Burns Joseph P, Barber F Alan, Wodicka Ross, Getelman Mark H, Karzel Ronald P, Snyder Stephen J

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: The primary purpose of this study was to evaluate the repair integrity on magnetic resonance imaging (MRI), and secondarily, clinical outcomes, of medium to large (2-4 cm) rotator cuff tears treated using an arthroscopic triple-loaded medially based single-row repair technique augmented laterally with bone marrow vents.

METHODS

This is a retrospective outcomes study of patients with full-thickness medium to large (2-4 cm) rotator cuff tears repaired by 4 surgeons at a single institution over a 2-year period with a minimum of 24 months' follow-up. A single-row repair with tension-minimizing medially based triple-loaded anchors and laterally placed bone marrow vents was used. Patients completed a satisfaction and pain survey, the Western Ontario Rotator Cuff index questionnaire, and a Short Form-36 version 2 survey to evaluate clinical outcomes. MRI was obtained at a minimum of 24 months follow-up to assess repair integrity.

RESULTS

A total of 64 males and 27 females with a mean age of 59.7 (range, 34-82) were included. The mean tear size was 2.6 cm in anteroposterior dimension, treated with a mean of 2.2 anchors. Eighty-three of 91 shoulders (91%) reported being completely satisfied with their result. The median Western Ontario Rotator Cuff score was 95.2% of normal, with a significant difference found between those with an intact repair and those with a full-thickness recurrent defect (median, 95.9% vs. 73.8%; P = .003). Postoperative MRI obtained at a median of 32 months (range, 24-48) demonstrated an intact repair in 84 of 91 shoulders (92%), with failure defined as a full-thickness defect of the tendon.

CONCLUSIONS

Arthroscopic repair of medium to large rotator cuff tears using triple-loaded medially based single-row repair augmented with marrow vents resulted in a 92% healing rate by MRI and excellent patient-reported outcomes LEVEL OF EVIDENCE: Level IV, retrospective case series.

Для цитирования: Dierckman Brian D, Frousiakis Petros, Burns Joseph P, Barber F Alan, Wodicka Ross, Getelman Mark H, Karzel Ronald P, Snyder Stephen J. Arthroscopic Repair of Medium to Large Rotator Cuff Tears With a Triple-Loaded Medially Based Single-Row Technique Augmented With Marrow Vents.. Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association. 2020. DOI: 10.1016/j.arthro.2020.08.003.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.