MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.watres.2025.124332

Медицинская библиотека · Water research · 2025

Polarization electric field tuning interface electric field in full-spectral response double S-scheme heterojunction to drive synchronous removal of Cr(VI) and RBR X-3B.

Bai Jing, Zhang Xiangling, Wang Chen, Li Xuhao, Cao Shilong, Zhang Rong, Hu Jiezhou

СтатьяПеревод в очереди

Аннотация

Photocatalytic technology provides a sustainable development strategy for the synchronous removal of azo dyes and mordant leaching of Cr(VI). To mitigate the shielding effect of free carriers on the built-in electric field during the photocatalytic process, a double S-scheme piezo-photocatalyst Bi2WO6/BiOCl/Bi2S3 (BW-C-S) with full spectral response that can continuously respond to the ultrasound-guided polarized electric field to adjust the built-in electric field to promote the separation and migration of photogenerated carriers was developed. BW-C-S effectively overcame the barriers of carrier separation and migration by utilizing an ultrasonic-optical coupling field, achieving the rapid synchronous removal of reactive brilliant red X-3B (RBR X-3B) (0.057 min-1) and Cr(VI) (0.063 min-1). The synergistic reaction mechanism, potential degradation pathways, and the ecological toxicity of intermediates associated with the RBR X-3B/Cr(VI) synchronous removal process and the RBR X-3B independent degradation process were further elucidated through LC-MS analysis, DFT calculations, and toxicity evaluations. The continuous removal efficiency of pollutants by BW-C-S under dynamic hydraulic conditions was validated through the construction of a continuous flow reaction device, which provided theoretical support for the sustainable purification of various pollutants in complex aquatic environments.

Для цитирования: Bai Jing, Zhang Xiangling, Wang Chen, Li Xuhao, Cao Shilong, Zhang Rong, Hu Jiezhou. Polarization electric field tuning interface electric field in full-spectral response double S-scheme heterojunction to drive synchronous removal of Cr(VI) and RBR X-3B.. Water research. 2025. DOI: 10.1016/j.watres.2025.124332.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.