Continuous-flow mechanical circulatory support is not associated with early graft failure: An analysis of the International Society for Heart and Lung Transplantation registry.

Clerkin Kevin J, Mancini Donna M, Stehlik Josef, Cherikh Wida S, Lund Lars H

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Continuous-flow mechanical circulatory support (CF-MCS) is associated with impaired vascular function and increased risk of vasoplegia. One contributing factor to early graft failure (EGF) is severe vasoplegia. We tested the hypothesis that CF-MCS is associated with increased risk of EGF.

METHODS

Adult primary heart transplant recipients in the ISHLT Registry from 2005 to 2013 were stratified into three groups based on pre-transplant MCS: No MCS (n = 11 748), pulsatile (P)-MCS (n = 718), and CF-MCS (n = 3818). EGF was defined as death/retransplantation due to graft failure within 30 days after HT. Comparisons were made using descriptive statistics and associations. EGF was assessed with multivariable Cox proportional hazard regression.

RESULTS

The incidence of EGF within 30 days was similar between groups (No MCS 2.2%, P-MCS 3.3%, CF-MCS 2.1%, P = .10). Following multivariable adjustment, the risk of EGF was not statistically different for those with CF-MCS compared with P-MCS (HR 0.75, 95% CI 0.46-1.21, P = .24). The risk of EGF was numerically, but not statistically significantly higher for CF-MCS compared with No MCS (HR 1.24, 95% CI 0.92-1.67, P = .16).

CONCLUSION

CF-MCS use was not associated with a statistically significant increased risk of EGF resulting in death or retransplantation in the first 30 days after transplant.

Для цитирования: Clerkin Kevin J, Mancini Donna M, Stehlik Josef, Cherikh Wida S, Lund Lars H. Continuous-flow mechanical circulatory support is not associated with early graft failure: An analysis of the International Society for Heart and Lung Transplantation registry.. Clinical transplantation. 2019. DOI: 10.1111/ctr.13752.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.