MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/trf.15083

Медицинская библиотека · Transfusion · 2018

Seasonal variability is not observed in the rates of high anti-A and anti-B titers in plasma, apheresis platelet, and whole blood units tested by different methods.

Harm Sarah K, Yazer Mark H, Bub Carolina B, Cohn Claudia S, Jacob Eapen K, Kutner Jose M, Mair David C, Raval Jay S, Shaz Beth H, Ziman Alyssa, Dunbar Nancy M, Biomedical Excellence for Safer Transfusion (BEST) Collaborative

СтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

ABO-incompatible platelet transfusions are common, and transfusions with ABO-incompatible plasma are increasing with the use of group A plasma and group O whole blood (WB) in emergencies. Many centers screen blood products for anti-A and/or anti-B titers to help prevent hemolysis from ABO-incompatible transfusions, yet titer methods and definition of high titers are not standardized.

STUDY DESIGN AND

METHODS

This international multicenter study collected data on anti-A and anti-B titer practices for plasma, apheresis platelet (AP), and WB units from January 2015 through December 2017 to determine the prevalence of high-titer units using local definitions.

RESULTS

A total of 87,701 plasma, AP and WB units were screened for high-titer anti-A and/or anti-B. High-titer detection rates for group A plasma ranged 0%-13.6%; group A AP 2.7%-9.3%; group O AP 2.3%-65.7%; and group O WB 6.4%-20.7%. At the one center that collected group B AP, the high-titer rate was 10.9%. High-titer rates varied from month to month, as well as between years for a given month. There was no clear pattern of when high-titer units were donated.

CONCLUSION

The prevalence of high-titer plasma, AP, and WB units varies by titer method and local definition of high titer. Even at the lowest titer threshold of 50, a significant proportion of units had a high-titer antibody, although the clinical relevance of this finding needs further investigation.

Для цитирования: Harm Sarah K, Yazer Mark H, Bub Carolina B, Cohn Claudia S, Jacob Eapen K, Kutner Jose M, Mair David C, Raval Jay S, Shaz Beth H, Ziman Alyssa, Dunbar Nancy M, Biomedical Excellence for Safer Transfusion (BEST) Collaborative. Seasonal variability is not observed in the rates of high anti-A and anti-B titers in plasma, apheresis platelet, and whole blood units tested by different methods.. Transfusion. 2018. DOI: 10.1111/trf.15083.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.