MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.arthro.2004.04.057

Медицинская библиотека · Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association · 2004

Glenohumeral arthroscopy portals established using an outside-in technique: neurovascular anatomy at risk.

Lo Ian K Y, Lind Charles C, Burkhart Stephen S

СтатьяПеревод в очереди

Аннотация

PURPOSE: The purpose of this study was to examine the neurovascular structures at risk during placement of glenohumeral arthroscopy portals using an outside-in technique.

TYPE OF STUDY: Anatomic cadaveric study.

METHODS

Five fresh-frozen cadaveric specimens were used in this study. Each shoulder was mounted on a custom-designed apparatus allowing shoulder arthroscopy in a lateral decubitus position. The following portals were established using an outside-in technique and marked using an 18-gauge spinal needle: posterior, posterolateral, anterior, 5-o'clock, anterosuperolateral, and Port of Wilmington. Each specimen was carefully dissected after the procedure, and the distance from each portal site to the adjacent relevant neurovascular structures (axillary nerve, musculocutaneous nerve, lateral cord of the brachial plexus, cephalic vein, and axillary artery) was measured using a precision caliper.

RESULTS

Except for the cephalic vein, all of the neurovascular structures were more than 20 mm away from all the portals evaluated. When creating either an anterior portal or a 5-o'clock position portal, the mean distance from the portal to the cephalic vein was 18.8 mm and 9.8 mm, respectively. In one anterior portal, a direct injury to the cephalic vein occurred.

CONCLUSIONS

Our study suggests that shoulder arthroscopy portals placed in an outside-in fashion are unlikely to produce neurologic injury. However, the cephalic vein is at risk during placement of an anterior or 5-o'clock position portal, although probably with minimal subsequent patient morbidity. Placing portals in an outside-in fashion guarantees the correct angle of approach, with minimal risk to adjacent neurologic structures.

CLINICAL RELEVANCE: This study shows the safety of standard and accessory glenohumeral arthroscopy portals.

Для цитирования: Lo Ian K Y, Lind Charles C, Burkhart Stephen S. Glenohumeral arthroscopy portals established using an outside-in technique: neurovascular anatomy at risk.. Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association. 2004. DOI: 10.1016/j.arthro.2004.04.057.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.