m+Medelevator.RU
← Поиск публикаций
Journal of vascular and interventional radiology : JVIR · 2026

Stereotactic Percutaneous Thermal Ablation of Primary and Metastatic Liver Tumors: A Prospective Registry-Based Study.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Paolucci Iwan, Albuquerque Jessica, Siddiqi Noreen S, Patel Milan, Shah Ketan Y, Huang Steven, Sheth Rahul A, Metwalli Zeyad A, Avritscher Rony, Brock Kristy K, Jones A Kyle, Jackson Timothy A, Wang Mi, Ruiz Joseph, Tan Jens, Kuban Joshua D, Lin Ethan Y, Bale Reto, Odisio Bruno C

Аннотация

PURPOSE: To prospectively evaluate safety, accuracy, and effectiveness of stereotactic thermal ablation of malignant liver tumors at a large academic center in the United States.

MATERIALS AND METHODS: From June 2023 to November 2024, 100 thermal liver ablation procedures were performed using CAS-One IR (CAScination, Bern, Switzerland), a stereotactic image-guidance device, by 8 board-certified interventional radiologists. Ninety-six patients (median age, 58 years; male, 69%) undergoing 100 procedures for 164 liver tumors were included. General anesthesia with complete neuromuscular blockade was delivered with breath holds or high-frequency jet ventilation (HFJV) for respiratory control. Lateral targeting errors and their correlation with body mass index (BMI) and respiratory control, procedure times, short-term local outcomes, and adverse events (AEs) per Common Terminology Criteria for Adverse Events (CTCAE) v5 are reported. The Wilcoxon rank-sum test was used to compare lateral errors, and Kaplan-Meier survival analysis was used to estimate the cumulative incidence of local tumor progression (LTP).

RESULTS: The median tumor diameter was 1.6 cm (interquartile range, 1.1-2.4 cm). The median lateral targeting errors were 5.6 mm and 3.6 mm for breath holds and HFJV, respectively. BMI was positively correlated with lateral targeting error for breath holds (R = 0.26, P = .005). The LTP rates were 5.6% at 6 months and 7.4% at 12 months. Four CTCAE Grade 3 AEs (4%) occurred: 3 bleeding events (2 device-related) and 1 brachial plexus injury.

CONCLUSIONS: Stereotactic thermal ablation of liver tumors demonstrated similar safety, targeting accuracy, and oncologic outcomes to reported European data. These findings support its utility in thermal ablation of liver tumors in U.S.-based clinical practice.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты