Case report: 2 cases of cardiac arrest caused by rhino-cardiac reflex while disinfecting nasal cavity before endonasal transsphenoidal endoscopic pituitary surgery.

Wang Wen, Cai Hongwei, Ding Huiping, Xu Xiaoping

Клинический случайСтатьяПеревод в очереди

Аннотация

BACKGROUND

Trigeminal-cardiac reflex (TCR) is a brainstem vagus reflex that occurs when any center or peripheral branch of the trigeminal nerve was stimulated or operated on. The typical clinical manifestation is sudden bradycardia with or without blood pressure decline. The rhino-cardiac reflex which is one type of TCR is rare in clinical practice. As the rhino-cardiac reflex caused by disinfection of the nasal cavity is very rare, we report these two cases to remind other anesthesiologists to be vigilant to this situation.

CASE PRESENTATION: This case report describes two cases of cardiac arrest caused by rhino-cardiac reflex while disinfecting nasal cavity before endoscopic transsphenoidal removal of pituitary adenomas. Their heart rate all dropped suddenly at the very moment of nasal stimulation and recovered quickly after stimulation was stopped and the administration of drugs or cardiac support.

CONCLUSION

Although the occurrence of rhino-cardiac reflex is rare, we should pay attention to it in clinical anesthesia. It is necessary to know the risk factors for preventing it. Once it occurs, we should take active and effective rescue measures to avoid serious complications.

Для цитирования: Wang Wen, Cai Hongwei, Ding Huiping, Xu Xiaoping. Case report: 2 cases of cardiac arrest caused by rhino-cardiac reflex while disinfecting nasal cavity before endonasal transsphenoidal endoscopic pituitary surgery.. BMC anesthesiology. 2021. DOI: 10.1186/s12871-021-01240-w.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.