Медицинская библиотека · The Journal of heart valve disease · 2003

The use of a rigid instrument prior to stentless valve implantation facilitates correct alignment of the prosthesis and native aortic valve apparatus.

Quigley Robert L

СтатьяПеревод в очереди

Аннотация

BACKGROUND AND AIM OF THE STUDY: When correctly seated in the aortic position, stentless valves are associated with a relatively low transvalvular gradient. This leads to regression of left ventricular hypertrophy and long-term survival. The alleged complexity of stentless valve implantation has led to a preference for stented/mechanical prostheses. Here, the use of a rigid instrument to prevent technical complications after stentless valve implantation was investigated.

METHODS

Aortic valve replacement was performed in 75 patients (44 males, 31 females; mean age 72 years; range: 33-89 years) using the Toronto Stentless Porcine Valve (TSPV). Among patients, 37% had coronary artery bypass grafting and 3% mitral valve replacement. Valve size was either 23-25 mm (65%) or 21 mm (35%) and determined by sinotubular junction diameter. A rigid instrument was designed that mimics actual valve shape and accounted for valve dimensional variations and asymmetries on a size-by-size basis. The instrument was used to mark the site of the inflow and outflow suture lines and to determine orientation of the muscle bar on the prosthetic valve. Intraoperative transesophageal echocardiography was used to monitor all patients.

RESULTS

The mean intraoperative mean systolic peak pressure gradient (all valves) was 18.35 +/- 9.41 mmHg; there were no paravalvular leaks. Among patients, 22% had central trace aortic insufficiency, and one patient developed renal failure that required hemodialysis. There were no cerebral vascular accidents/infections, but one perioperative myocardial infarction occurred. There were four postoperative deaths, but none was valve-related.

CONCLUSION

Routine use of the instrument may avoid many risks during TSPV implantation. The device permits the surgeon to accommodate variation in the angle between the coronary ostia, as well as in the distance between these ostia and the native annulus.

Для цитирования: Quigley Robert L. The use of a rigid instrument prior to stentless valve implantation facilitates correct alignment of the prosthesis and native aortic valve apparatus.. The Journal of heart valve disease. 2003.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.