MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s13019-024-03215-7

Медицинская библиотека · Journal of cardiothoracic surgery · 2025

Application of low-intensity anticoagulation after On-X mechanical aortic valve replacement.

Zou Kun, Wei Dachuang, Xiang Bo, Yu Tao, Huang Keli, Liu Shengzhong

СтатьяРандомизированное исследованиеПеревод в очереди

Аннотация

OBJECTIVE

To explore the safety and efficacy of low-intensity anticoagulation in patients after On-X mechanical aortic valve replacement.

METHODS

A total of 104 patients undergoing aortic valve replacement in Cardiac Surgery Department of Sichuan Provincial People's Hospital from December 2018 to December 2021 were randomly divided into low-intensity anticoagulant (INR:1.5-2.0) and high-intensity anticoagulant (INR:2.0-2.5) to compare the incidence of adverse events related to postoperative anticoagulation between the two groups.

RESULTS

Fifty-three patients were included in the low-intensity anticoagulation group (INR 1.5-2.0), and 51 patients were included in the high-intensity group (2.0-2.5). There was no significant difference in baseline data and surgical index between the two groups (P > 0.05); there were statistically significant differences in PT, INR and bleeding events (P < 0.05), but no significant difference in embolic events (P > 0.05).

CONCLUSION

For patients requiring On-X mechanical aortic valve replacement who have no risk factors for thromboembolism, it is appropriate to control the INR in the target range 1.5-2.0, which can reduce the incidence of bleeding adverse events and significantly improve the quality of life, without increasing the risk of thromboembolic adverse events.

Для цитирования: Zou Kun, Wei Dachuang, Xiang Bo, Yu Tao, Huang Keli, Liu Shengzhong. Application of low-intensity anticoagulation after On-X mechanical aortic valve replacement.. Journal of cardiothoracic surgery. 2025. DOI: 10.1186/s13019-024-03215-7.