DOI 10.1186/s13019-024-03215-7
Application of low-intensity anticoagulation after On-X mechanical aortic valve replacement.
Аннотация
OBJECTIVE
To explore the safety and efficacy of low-intensity anticoagulation in patients after On-X mechanical aortic valve replacement.
METHODS
A total of 104 patients undergoing aortic valve replacement in Cardiac Surgery Department of Sichuan Provincial People's Hospital from December 2018 to December 2021 were randomly divided into low-intensity anticoagulant (INR:1.5-2.0) and high-intensity anticoagulant (INR:2.0-2.5) to compare the incidence of adverse events related to postoperative anticoagulation between the two groups.
RESULTS
Fifty-three patients were included in the low-intensity anticoagulation group (INR 1.5-2.0), and 51 patients were included in the high-intensity group (2.0-2.5). There was no significant difference in baseline data and surgical index between the two groups (P > 0.05); there were statistically significant differences in PT, INR and bleeding events (P < 0.05), but no significant difference in embolic events (P > 0.05).
CONCLUSION
For patients requiring On-X mechanical aortic valve replacement who have no risk factors for thromboembolism, it is appropriate to control the INR in the target range 1.5-2.0, which can reduce the incidence of bleeding adverse events and significantly improve the quality of life, without increasing the risk of thromboembolic adverse events.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.