DOI 10.1016/j.jpurol.2024.01.006
Teaching hypospadias repair by utilising a novel 3D-printed silicon model: An initial assessment using structured trainee and trainer feedback.
Аннотация
INTRODUCTION
Simulated paediatric surgical training is inherently advantageous and flourishing. Moreover, several working conditions resulted in reduced training hours, index and subspecialty cases encountered, and the COVID-19 pandemic affected elective surgery backlogs, hence training opportunities. Hypospadias repair is technically-demanding and requires a spectrum of dissective and reconstructive skills. We therefore aimed to test a 3D-printed silicon model for hypospadias repair, in the context of hands-on surgical training.
MATERIAL AND
METHODS
Twenty-Seven trainees, under the supervision of 15 instructors, completed the activity. They were given a seminar to show the relevant anatomy, and 8 key steps of the exercise: (1)-degloving; (2)-urethral plate marking; (3)-incision; (4)-tubularisation; (5)-glansplasty/glanuloplasty; (6)-dartos layer preparation; (7)-preputioplasty and (8)-skin closure. Each trainee completed a structured feedback assessment. An on-site trainer supervised and evaluated each exercise. Trainees and trainers rated the model through the above steps from unsatisfactory-(1/5) to excellent-(5/5), presented herein via cross-sectional analysis.
RESULTS
Eleven-(40.7 %) trainees were in years:1-3 of specialist training, 10-(37 %) were in years:4-6, and 6-(22.2 %) were beyond year-6. Two-(7.4 %) trainees had nil-hypospadias experience, 16-(59.2 %) previously assisted in procedures or performed steps, 5-(18.5 %) performed whole procedures supervised and 4-(14.8 %) independently. Twenty-(74 %) trainees and 15-(100 %) instructors judged the model to resemble the anomaly. Seventeen-(63 %) trainees and 13-(86.6 %) instructors rated the material needle-penetrability ≥3/5, compared to human tissue. Sixteen-(59 %) trainees and 13-(86.6 %) instructors rated the material suture holding ≥3/5. Eleven-(73.3 %) trainees and 13-(86.6 %) instructors rated sutures' evenness and edge coaptability ≥3/5.
DISCUSSION: Hypospadias is an index operation, which requires precision skills. Simulated training in Paediatric Surgery and Urology is gaining importance. 3D-printed models are gaining a key role in simulated training. The study presents a novel 3D-printed high-fidelity silicon-based hypospadias model designed for hands-on training. A structured pathway to divide a standard hypospadias repair into key steps is displayed to ensure skill acquisition and stabilisation.
CONCLUSION
This 3D-printed silicon-based hypospadias model is proven useful for hands-on training. The fidelity can still improve, especially regarding suture holding of the material.
LEVEL OF EVIDENCE: LEVEL III.