MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1021/acs.analchem.6c02416

Медицинская библиотека · Analytical chemistry · 2026

Multiplexed Detection of Breast Cancer-Specific miRNA and Protein Biomarkers on Exosomes Using a Microfluidic Platform.

Wang Hongqiang, Liu Hui, Luan Yanan, Du Bin, Wang Jun, Yang Yu, Yang Xiaohai, Wang Qing, Wang Kemin

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Exosomes, rich in diverse bioactive molecules, have emerged as a promising "liquid biopsy" approach for early cancer screening. However, relying solely on a single biomarker type can easily lead to missed diagnoses or misjudgments. Therefore, there is an urgent need to develop multiple biomarkers detection strategies to facilitate precise diagnosis. Herein, a microfluidic chip integrating two signals (ALP-driven chemiluminescence and nanobeacons-based fluorescence) into a single device was developed using breast cancer exosomes as a model. A simple sample injection enabled capture and quantitative detection of exosomal surface proteins (CD63, EpCAM, HER2) and internal miRNAs (miRNA-21, miRNA-375). After capture, protein levels were determined by driving magnetic beads and capturing images with a smartphone. Prefabricated nanobeacons were then directly introduced into the chip, enabling miRNA signal detection without RNA extraction. This five-marker biomarker panel achieved a diagnostic accuracy of 99.6% in breast cancer identification, representing an improvement of at least 4.6% over single-marker approaches and an 8.6% increase over any individual biomarker. This multitarget exosome analysis platform may provide a highly sensitive, low-cost, and easily scalable novel tool for breast cancer early diagnosis and treatment efficacy assessment.

Для цитирования: Wang Hongqiang, Liu Hui, Luan Yanan, Du Bin, Wang Jun, Yang Yu, Yang Xiaohai, Wang Qing, Wang Kemin. Multiplexed Detection of Breast Cancer-Specific miRNA and Protein Biomarkers on Exosomes Using a Microfluidic Platform.. Analytical chemistry. 2026. DOI: 10.1021/acs.analchem.6c02416.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.