m+Medelevator.RU
← Поиск публикаций
Neurological research · 2024

Comparison of nylon, vicryl, and fibrin glue for nerve grafting in rats.

СтатьяСравнительное исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Hanna Amgad S, Mickelson Ethan, Omar Ahmed H, Baer Matthew, Sveum Jacob, Marti Taylor, Mishra Raveena, Trudrung Melissa, Hutchinson Jacob, Attaluri Pradeep, Jacobs Alison, Ott Emily, Martinson Natalie, Jones Jalon, Hellenbrand Daniel

Аннотация

OBJECTIVES: For nerve injuries, not amendable to tensionless epineural coaptation of the nerve, autografts are the preferred treatment. Although absorbable sutures are not recommended for nerve repair, there is no evidence that non-absorbable sutures are superior to absorbable sutures. This study aims to assess the effectiveness of non-absorbable monofilament nylon sutures, absorbable monofilament vicryl sutures, and fibrin glue when used for nerve grafting.

METHODS: Lewis rats (N = 32) were subjected to a sciatic nerve transection and randomly assigned to a group: graft with Nylon, graft with Vicryl, graft with Fibrin Glue, or no graft. Motor function, sensory function, and thermal pain were assessed during a 12-week recovery period, and immunohistochemistry was used to assess macrophage response.

RESULTS: At 12 weeks, the Vicryl and Nylon groups had significantly larger ankle angles at to lift off, which is a measure of motor function, compared to injured controls (p < 0.05). Grafted rats displayed no difference in thermal response but hypersensitivity to mechanical stimuli compared to the uninjured hindlimb. The Nylon, Vicryl, and Fibrin Glue groups all had significantly less atrophy of the gastrocnemius muscle compared to injured controls (p < 0.0001). In the Fibrin Glue group, 3/9 grafts did not incorporate. The Nylon group had significantly less (p = 0.0004) axon growth surrounding the suture holes compared to the Vicryl group. There were no differences in the axon counts, motor neurons, or sensory neurons between all grafted rats.

CONCLUSIONS: These results demonstrate that vicryl sutures work just as well as nylon for nerve recovery after injury and grafting.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты