European heart journal. Case reports · 2024
Pacemaker lead extraction saved a severe lead-induced tricuspid regurgitation: a case report.
Клинический случайСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Chai YuLiang, Liu Qiang, Chen Zhiwen, Zhang Wenjing, Liu Yuanqing
Аннотация
BACKGROUND: Pacemaker lead-induced tricuspid regurgitation is a common complication after cardiac implantable electronic device (CIED) implantation. Cardiac implantable electronic device lead removal is a challenge procedure.
CASE SUMMARY: A 72-year-old lady was admitted due to worsening heart failure. She had a history of permanent atrial fibrillation and had a permanent single-chamber pacemaker implanted 8 years ago due to complete heart block. Transthoracic echocardiography identified severe lead-related tricuspid regurgitation. The patient underwent successful lead extraction and received a new implantation of left bunch bundle area pacing. Transthoracic echocardiographic examination 2 days after the procedure showed a significant decrease of the tricuspid regurgitation. The patient also reported an improvement in heart failure symptoms.
DISCUSSION: Pacemaker lead-related tricuspid regurgitation introduces negative haemodynamic overload, carrying high risk for the development of heart failure and worse outcome. The present case shows a rapid relief of symptom and improvement of echocardiography findings, indicating the significance of mechanistic approach in the treatment of lead-related tricuspid mechanical interference.
CASE SUMMARY: A 72-year-old lady was admitted due to worsening heart failure. She had a history of permanent atrial fibrillation and had a permanent single-chamber pacemaker implanted 8 years ago due to complete heart block. Transthoracic echocardiography identified severe lead-related tricuspid regurgitation. The patient underwent successful lead extraction and received a new implantation of left bunch bundle area pacing. Transthoracic echocardiographic examination 2 days after the procedure showed a significant decrease of the tricuspid regurgitation. The patient also reported an improvement in heart failure symptoms.
DISCUSSION: Pacemaker lead-related tricuspid regurgitation introduces negative haemodynamic overload, carrying high risk for the development of heart failure and worse outcome. The present case shows a rapid relief of symptom and improvement of echocardiography findings, indicating the significance of mechanistic approach in the treatment of lead-related tricuspid mechanical interference.