MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/j.1699-0463.1988.tb05329.x

Медицинская библиотека · APMIS : acta pathologica, microbiologica, et immunologica Scandinavica · 1988

Comparative analysis of two blood culture systems (Isolator and a 12-tube system) by cumulative differences in detection power at different times during incubation.

Arpi M, Prag J, Schrøder S S, Bentzon M W, Frederiksen W

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

A lysis-centrifugation blood culture system (Isolator) and a conventional system (4 tubes of nutrient broth, 4 tubes of semisolid agar, and 4 tubes of thioglycollate agar) were compared after different lengths of incubation by cumulative scoring of differences in detection power. After the first half day of incubation, the Isolator system was already significantly faster in detecting isolates of clinical significance (15 vs. 4, P = 0.02). Maximum difference in first or only detection system was seen after two days of incubation and was based on an overall superior detection of Staphylococcus aureus (11 vs. 0, P = 0.001), and an earlier detection of Enterobacteriaceae (30 vs. 13, P = 0.01) in the Isolator system. On the contrary, the detection of Streptococcus pneumoniae was significantly inferior in the Isolator system (0 vs. 10, P = 0.002). The earlier finding of clinically significant microorganisms in the Isolator system certainly contributes to good patient-care. A drawback of the Isolator system was the finding of clinically insignificant coagulase-negative staphylococci in 11%, compared with 1% in the conventional system. This led to a considerable waste of time and materials in the laboratory. The comparison of the two blood culture systems, based on statistical analysis of cumulative differences in detection power, expressed as the earliest or only findings, gives the optimal information, and is in our opinion the clinically most relevant comparison.

Для цитирования: Arpi M, Prag J, Schrøder S S, Bentzon M W, Frederiksen W. Comparative analysis of two blood culture systems (Isolator and a 12-tube system) by cumulative differences in detection power at different times during incubation.. APMIS : acta pathologica, microbiologica, et immunologica Scandinavica. 1988. DOI: 10.1111/j.1699-0463.1988.tb05329.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.