MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jim.2017.08.005

Медицинская библиотека · Journal of immunological methods · 2017

Establishing tools for early diagnosis of congenital toxoplasmosis: Flow cytometric IgG avidity assay as a confirmatory test for neonatal screening.

de Castro Zacche-Tonini Aline, Fonseca Giuliana Schmidt França, de Jesus Laura Néspoli Nassar Pansini, Barros Geisa Baptista, Coelho-Dos-Reis Jordana Grazziela Alves, Béla Samantha Ribeiro, Machado Anderson Silva, Carneiro Ana Carolina Aguiar Vasconcelos, Andrade Gláucia Manzan Queiroz, Vasconcelos-Santos Daniel Vitor, Januário José Nélio, Teixeira-Carvalho Andréa, Vitor Ricardo Wagner Almeida, Ferro Eloísa Amália Vieira, Mineo José Roberto, Martins-Filho Olindo Assis, Lemos Elenice Moreira, UFMG Congenital Toxoplasmosis Brazilian Group - UFMG-CTBG

Оценочное исследованиеСтатьяПеревод в очереди

Аннотация

The aim of this study was to evaluate the performance of conventional serology (Q-Preven™ and ELFAVIDAS™) and flow cytometry-based serologic tools for early serologic diagnosis of congenital toxoplasmosis. The study groups included prospectively confirmed cases of congenital toxoplasmosis (TOXO=88) and age-matching non-infected controls (NI=15).The results demonstrated that all samples tested positive/indeterminate for anti-T. gondii IgM screening at birth using air-dried whole blood samples. Serum samples collected at 30-45days after birth tested positive for ELFAVIDAS™ IgG in both groups. While all NI tested negative for ELFAVIDAS™ IgM and IgA, only 78% and 36% of TOXO tested positive for IgM and IgA, respectively. Flow cytometry-based anti-T. gondii IgM, IgA and IgG reactivity displayed moderate performance with low sensitivity (47.6%, 72.6% and 75.0%, respectively). Regardless the remarkable specificity of IgG1, IgG2 and IgG3 subclasses for early diagnosis, weak or moderate specificity was observed (Se=73.9%, 60.2% and 83.0%, respectively). The analysis of IgG avidity indices (AI) demonstrated the highest performance among the flow cytometry-based methods (Se=96.6%; Sp=93.3%), underscoring the low avidity index (AI<60%) within TOXO (97.0%) in contrast with the high avidity index (AI>60%) in NI (93%). Analysis of anti-T. gondii IgG and IgG3 reactivity for mother:infant paired samples may represent a relevant complementary tests for early diagnosis. In conclusion, a feasible high-standard algorithm (Accuracy=97.1%) was proposed consisting of Q-Preven™ IgM screening at birth, followed by ELFAVIDAS™ IgM and flow cytometric IgG avidity analysis at 30-45days after birth as a high performance tool for early serological diagnosis of congenital toxoplasmosis.

Для цитирования: de Castro Zacche-Tonini Aline, Fonseca Giuliana Schmidt França, de Jesus Laura Néspoli Nassar Pansini, Barros Geisa Baptista, Coelho-Dos-Reis Jordana Grazziela Alves, Béla Samantha Ribeiro, Machado Anderson Silva, Carneiro Ana Carolina Aguiar Vasconcelos, Andrade Gláucia Manzan Queiroz, Vasconcelos-Santos Daniel Vitor, Januário José Nélio, Teixeira-Carvalho Andréa, Vitor Ricardo Wagner Almeida, Ferro Eloísa Amália Vieira, Mineo José Roberto, Martins-Filho Olindo Assis, Lemos Elenice Moreira, UFMG Congenital Toxoplasmosis Brazilian Group - UFMG-CTBG. Establishing tools for early diagnosis of congenital toxoplasmosis: Flow cytometric IgG avidity assay as a confirmatory test for neonatal screening.. Journal of immunological methods. 2017. DOI: 10.1016/j.jim.2017.08.005.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.